GF 400 DV Sebago
Specifications
Input Rates
Natural Gas
32,000 BTU/hr. maximum input
18,000 BTU/hr. minimum input
Propane
32,000 BTU/hr. maximum input
16,000 BTU/hr. minimum input
Inlet Pressure: | MIN | MAX |
Natural Gas: | 5.0 WC (1.24 kPa) | 7.0 WC (1.74 kPa) |
Propane: | 12.0 WC (2.99 kPa) | 14.9 WC (3.71 kPa) |
Manifold Pressure: MIN | MAX | |
Natural Gas: | 1.2 WC (.30 kPa) | 3.8 WC (.95 kPa) |
Propane: | 2.9 WC (.722 kPa) | 11.0 WC (2.74 kPa) |
Piezo Ignitor / Standing Pilot
Suggested Tools for
Installation and Service
•External regulator (for Propane only)
•Piping which complies with local code
•Manual shutoff valve
•Sediment trap - if required by code
•Tee joint
•Pipe wrench
•Pipe sealant
•10 mm open end wrench
•1/2”, 7/16” open end wrench or deep socket
•Phillips head screwdriver
•Flat head screwdriver
•1/4” nut driver
•4 mm allen wrench
•Gloves
•Safety glasses
•Torx T20 screwdriver
•Leak test solution
•Reciprocating Saw
•Power Drill
28 1/2”
724 mm
26 1/2”
673 mm
13”
330 mm
26 1/2”
673 mm
C
L
28 1/2”*
724 mm
25 1/2”*
647 mm
19 5/8”
500 mm
29”
737 mm
19 1/2”
495 mm
*For height with 6” Legs, subtract 2 1/4”