95
Format /api/param?network.ntp.interval=data
Example /api/param?network.ntp.interval=60
Example of Response
network.ntp.interval&202 Accepted(network.ntp.status=restart)
Interpretation Change the interval for accessing the NTP server. Unit can be set by "network.ntp.unit" API. Specify
1-60 when the unit is min/hour, 1-31 when the unit is day. To validate the change, use "network.ntp.status=restart" API.
Allowed users admin, operator
Getting Access Interval Unit of NTP from VN-V685/686/686B
Format /api/param?network.ntp.unit
Example of Response network.ntp.unit=hour&200 OK
Interpretation Acquire the unit of interval for accessing the NTP server. "min", "hour" or "day" is returned.
Allowed users admin, operator, user
Setting Access Interval Unit of SNTP for VN-V685/686/686B
Format /api/param?network.ntp.unit=data
Example /api/param?network.ntp.unit=day
Example of Response
network.ntp.unit&202 Accepted(network.ntp.status=restart)
Interpretation Change the unit of interval for accessing the NTP server. Specify "min", "hour" or "day". To validate
the change, use "network.ntp.status=restart" API.
Allowed users admin, operator
Getting Time from VN-V685/686/686B
Format /api/param?system.date
Example of Response system.date=20050614171537&200 OK
Interpretation Acquire the time from the built-in clock of VN-V685/686/686B. Time is arranged in the order of year,
month, day, hour, minute and second. Year is denoted in a 4-digit decimal number, and month, day, hour, minute and
second are denoted in 2-digit decimal numbers.
Allowed users admin, operator, user
Setting Time for VN-V685/686/686B
Format /api/param?system.date=data
Example /api/param?system.date=20050614171537
Example of Response system.date&200 OK
Interpretation Change the time of the built-in clock in VN-V685/686/686B. Specify in the order of year, month, day,