system.session.sending(01).from.framerate=1&200 OK

system.session.sending(01).from.framesize=vga&200 OK

In case of MPEG-4, system.session.sending(01).from.encode=mpeg4 is returned. In case of multicast, system.session.sending(01).to.ip becomes multicast IP address.

Interpretation Acquire the sending status of VN-V685/686/686B. Starting and stopping stream can be occurred in random order, so it can happen that sending(01) is vacant though sending(02) has information.

Allowed users admin, operator, user

Getting Log

Format /api/param?system.log

Response Return the following information. These information will be initialized upon turning off the power of VN-V685/686/686B.

Number of seconds after startup, Alarm input, Motion detect, Error

Response examples

system.log=&200 OK

 

 

 

system alive time: 2142sec <-----

No. of seconds after startup

 

Dec 19

14:35:32 vn-v685 user.info evman: Motion Detect

<-----

Motion detect

Dec 19

14:36:03 vn-v685 user.info evman: Alarm Detect (m1) <-----

Alarm input 1ch (make)

Dec 19

14:36:04 vn-v685 user.info evman: Alarm Detect (b2) <-----

Alarm input 2ch (break)

Dec 19

14:35:18 vn-v685 user.info evman: Motion Detect

<-----

Motion detect

Interpretation Acquire the VN-V685/686/686B log. Maximum size is 10KB.

Allowed user admin

6.19. Getting Settings

The APIs below are related to the acquisition of settings. These are equivalent to the features on the Settings page of the WEB setting page. Refer to the instruction manual for details on the Settings page.

Getting Model Name

Format /api/param?system.model

Example of Response system.model=VN-V685U/686U/686BU&200 OK

Interpretation Acquire the model name.

Allowed users admin, operator, user

Getting Firmware Revisions of Streaming Manager

100

Page 100
Image 100