100
system.session.sending(01).from.framerate=1&200 OK
system.session.sending(01).from.framesize=vga&200 OK
In case of MPEG-4, system.session.sending(01).from.encode=mpeg4 is returned. In case of multicast,
system.session.sending(01).to.ip becomes multicast IP address.
Interpretation Acquire the sending status of VN-V685/686/686B. Starting and stopping stream can be occurred in
random order, so it can happen that sending(01) is vacant though sending(02) has information.
Allowed users admin, operator, user
Getting Log
Format /api/param?system.log
Response Return the following information. These information will be initialized upon turning off the power of
VN-V685/686/686B.
Number of seconds after startup, Alarm input, Motion detect, Error
Response examples
system.log=&200 OK
system alive time: 2142sec <----- No. of seconds after startup
Dec 19 14:35:32 vn-v685 user.info evman: Motion Detect <----- Motion detect
Dec 19 14:36:03 vn-v685 user.info evman: Alarm Detect (m1) <----- Alarm input 1ch (make)
Dec 19 14:36:04 vn-v685 user.info evman: Alarm Detect (b2) <----- Alarm input 2ch (break)
Dec 19 14:35:18 vn-v685 user.info evman: Motion Detect <----- Motion detect
Interpretation Acquire the VN-V685/686/686B log. Maximum size is 10KB.
Allowed user admin

6.19. Getting Settings
The APIs below are related to the acquisition of settings. These are equivalent to the features on the Settings page of the
WEB setting page. Refer to the instruction manual for details on the Settings page.
Getting Model Name
Format /api/param?system.model
Example of Response system.model=VN-V685U/686U/686BU&200 OK
Interpretation Acquire the model name.
Allowed users admin, operator, user
Getting Firmware Revisions of Streaming Manager