Interpretation Change port number for control of FTP server that is used by alarm action. Default is 21. Port number

for data plus one is the port number for control.

Allowed user admin, operator

7.List of Protocols and Port Numbers Used with VN-V685/686/686B

VN-V685/686/686B uses the following protocols and port numbers.

Protocol / Port Number

Use

TCP 80

WEB setting page, API for Getting status and changing

 

settings, acquisition of JPEG from VN-V685/686/686B by

 

client

UDP 80

Search for VN-V685/686/686B

TCP 20, 21

FTP

TCP 25

SMTP (Mail by Alarm Action)

TCP 110

POP (Mail by Alarm Action)

UDP 123

SNTP

TCP 5510

VSIP (Proprietary Protocol of Verint Systems Inc)

UDP 5510

VSIP (Proprietary Protocol of Verint Systems Inc)

UDP 9131

AMX Device Discovery Protocol

UDP 9541

VSIP (Proprietary Protocol of Verint Systems Inc)

TCP 10020, 10021, 10023

reserved for internal use

TCP User Setting

Alarm on TCP

UDP User Setting

Alarm on UDP

UDP User Setting

Multicast Streaming

8. Customizing VN-V686/685/686B’s Built-in Viewer

The built-in viewer of VN-V686/685/686B consists of three ActiveX controls. These ActiveX controls are available

for customized viewer.

8.1. List of ActiveX

- JPEG Viewer

It can show JPEG video, and save still image.

- MPEG-4 Viewer

It can show MPEG-4 video.

- PTZ Control Client

It can control digital ptz.

How to download ActiveX controls:

i)Please input URL below in Internet Explorer’s url form. <VN-V686>

http://(IP Address)/v686j.cab

... JPEG Viewer

http://(IP Address)/v686m.cab

... MPEG-4 Viewer

http://(IP Address)/v686ptz.cab

... PTZ Control Client

103

Page 103
Image 103
JVC 686BU, 686U, VN-V685U manual List of ActiveX, 103