13. OTHERS

Warning Indications for VCR Abnormalities

Should malfunctions occur during VCR operation, the unit self-diagnoses the cause and shows the diagnose together with an error code on the LCD monitor or in the viewfinder.

Error code

*1 If the unit is used in a state where the cassette cover is open after inserting a cassette tape, there can be a case where an error code “3200, 7202, 7302” appears.

WARNING7001

DRUM MOTOR FAILURE

Warning

In such a case, switch off the power once and switch it on again, and then close the cassette cover before use.

Error Code

Error Details

 

GY-DV5000 Operation

Remedy

 

 

 

 

0201

Indicates dew formation

Operation stops. All operations

Leave the unit with the power ON,

CONDENSATION ON DRUM

(condensation)

 

are rejected.

until the indication disappears.

 

 

 

 

 

 

 

 

 

3200

Tape cannot be loaded.

 

Switch the power OFF and then

 

LOADING FAILURE

 

*1

 

switch it back ON. However, the

 

 

 

 

tape may be damaged depending

 

 

 

 

3300

Tape cannot be unloaded.

 

on the circumstances. Please

UNLOADING FAILURE

 

 

 

consult the person in charge of

 

 

 

 

professional video equipment at

 

 

 

 

4100

Irregularity with eject

 

 

your nearest JVC-authorized

CASSETTE EJECT FAILURE

operation.

 

 

service agent.

 

 

 

 

 

TAPE DEFECTIVE

Tape is cut.

 

Operation stops.

Press the EJECT button to take

5605 ~ 5609

 

 

 

out the cassette.

 

 

 

 

 

5702

Tape end sensor error.

 

Operation stops. All operations

Switch the power OFF and then

TAPE END DET. ERROR

 

 

are rejected.

switch it back ON. However, the

 

 

 

 

tape may be damaged depending

 

 

 

 

5802

Tape beginning sensor

 

on the circumstances. Please

TAPE BEGIN DET. ERROR

error.

 

 

consult the person in charge of

 

 

 

 

professional video equipment at

7001

Drum rotation error.

 

 

 

 

your nearest JVC-authorized

DRUM MOTOR FAILURE

 

 

 

service agent.

 

 

 

 

 

7101

Capstan rotation error.

 

 

 

CAP MOTOR FAILURE

 

 

 

 

 

 

 

 

 

7202 ~ 7203

Supply reel rotation

 

 

 

SUPPLY REEL FAILURE

error.

*1

 

 

7302 ~ 7303

Take up reel rotation

 

 

 

TAKE UP REEL FAILURE

error.

*1

 

 

7305

Irregular tape winding

 

 

TAKE UP REEL FAILURE

when unloading.

 

 

 

 

 

 

 

7401

Reel motor rotation error.

 

 

REEL MOTOR FAILURE

 

 

 

 

 

 

 

 

TURN POWER OFF.

System error when power

MODE indicator and TALLY

Turn off the power and let the unit

TURN BACK ON LATER.

is turned on.

 

lamp flash. Only Power switch

sit for sometime before turning it

 

 

 

operation is accepted.

back on.

 

 

 

 

 

TALLY lamp

Blinks when remaining battery power or tape is low. (Only in Camera mode)

Blinking Pattern

Remaining Battery/Tape

 

 

Slow blinking

Remaining battery power is low.

(once per sec.)

Remaining tape time is equivalent to less than 3 minutes.

 

 

Fast blinking

Tape has run out.

(four times per sec.)

Irregularity has occurred in the VCR.

 

 

E-91

Page 91
Image 91
JVC GY-DV5001 Error Code Error Details GY-DV5000 Operation Remedy, Tally lamp, Blinking Pattern Remaining Battery/Tape