4.6Service mode
4.6.1 Standard input/output conditions
Power supply voltage | DC14.4V(11 to 16V) |
Load impedance | 4Ω (2 Speakers connection) |
Line Output | 20KΩ |
4.6.2 Service mode setting procedure
(The DVD does not need to be loaded before starting the following procedure.)
[STANDBY/ON ATTENUATOR] button [MENU] button
[OK] button | [EJECT] button |
|
[UP] button
[DISPLAY] button
[B.SKIP] button | [BACK] button | [F.SKIP] button |
| [DOWN] button |
|
4.6.3Operation procedures
1.Service mode 1 (Indication is displayed in SERVICE MODE.)
Keep this state more than 2 seconds while continuing pressing the [STANDBY/ON ATTENUATOR] button and [EJECT] button sequentially.
Screen indication
SERVICE MODE
NO EJECT 1 EMERGENCY EJECT 2
Exchanging it operate a menu of a service mode with the [UP] button and [DOWN] button. Operate choice of a menu with a [OK] button.
1 : When an [OK] button is pushed in NO EJECT indication, it is set by an EJECT prohibition mode.
When an [OK] button is pushed in EJECT OK indication, it is set by a normal mode.
2 : Forced EJECT movement
A screen becomes normal indication after an OK button was pushed.