9 OPTIONAL SA-K97U RS-232C INTERFACE BOARD

E model

 

After transmitting the VISS SEARCH command (18), transmit the appropriate 2-byte numeric data (from 30H to 39H), the data input command

(40H), and either FF (ABH) or REW (ACH). All commands should be transmitted separately one byte at a time with “ACK” (0AH) confirmation

from the VCR after each transmission. * Execute in the Stop mode.

(18) VISS SEARCH (B3H)

: To search for a designated alarm-input point on the tape.

The VCR starts search after returning “ACK”. When the specified point is reached, the VCR returns COMPLETION (01H). If the end or

beginning of the tape is reached before the specified point, the VCR returns NOT TARGET (05H).

This command differs from commands (16) and (17) only in that the FF (ABH) or REW (ACH) command is included separately.

2 VCR setting commands

 

Commands available include control of recording/playback mode setting, timelapse VCR operation mode setting, date and time setting, timer

programming, on-screen setting, and others.

5Recording/playback mode setting commands

Two commands are available. One allows you to rotate through recording/playback modes, the other permits you to directly select the mode.

(1)MODE SHIFT (7DH) : Switches from one recording/playback mode to the next each time the command is transmitted. Use the TL STATUS SENSE (D6H) command to check the current mode.

(2)

MODE (7EH)

Transmit 1 byte at a time with “ACK” (0AH) confirmation from the VCR after each transmission.

: Sets recording/playback mode directly.

 

 

After transmitting this command, transmit the appropriate 2-byte ASCII codes (from 30H to 39H) and the data

 

 

input command (40H). Correspondence of ASCII codes with recording/playback modes is as shown below.

9 OPTIONAL SA-K97U RS-232C INTERFACE BOARD

5Date and time setting commands

(1)

DATE SET (8EH)

: Set the current date (month, day, year) for the VCR. After this command (8EH) is sent, input 1-

 

 

 

byte numerical data (30H — 39H).

 

 

 

 

 

 

 

 

 

 

 

 

 

(Example) Oct., 30, 1998

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TXD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8EH

 

31H

 

30H

 

33H

 

30H

39H

38H

 

 

Time

 

RXD

 

0AH

 

 

0AH

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

 

 

 

 

 

 

 

Month

 

 

 

Day

 

 

 

 

 

Year

 

 

 

 

 

(2)

TIME SET (8FH)

: Set the current time (hour, minute, second) for the VCR.

 

 

 

 

 

 

 

 

 

 

 

After this command (8FH) is sent, input 1-byte numerical data (30H — 39H).

 

 

 

(Example) 15 hours, 29 minutes, 59 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TXD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8FH

 

31H

 

35H

 

32H

 

39H

 

35H

 

39H

 

 

Time

 

 

RXD

 

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Eg: To set to “L24H”.

 

 

 

TXD

7EH

30H

 

33H

RXD

 

0AH

0AH

0AH

40H

0AH

Time

Mode

1st byte

2nd byte

3H

30H

30H

L12H

30H

32H

L24H

30H

33H

48H

30H

34H

72H

30H

35H

120H

30H

37H

168H

30H

38H

240H

30H

39H

480H

31H

31H

960H

31H

33H

Hour

Minute

Second

5Timer programming commands

(1)

PRG/CLK (62H)

: Engages timer programming mode.

(2)

SHIFT – (64H)

: Selects setting items. (–)

(3)

SHIFT + (63H)

: Selects setting items. (+)

SET – (66H)

: Sets data selected with SHIFT.

(4)

SET + (65H)

: Sets data selected with SHIFT.

CANCEL (67H)

: Cancels program data in timer programming or engages the Cancel Program mode.

Setting procedure is the same as when using the VCR controls. Be sure to transmit commands 1 byte at a time with “ACK” (0AH)

5Timelapse VCR operation mode setting commands

(1)

TL STATUS SET (86H)

: Set the timelapse VCR operation mode with 3-byte data. Send one byte at a time by checking

 

 

ACK (0AH) from the VCR.

 

 

 

 

 

 

 

 

 

TXD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

86H

 

 

 

1st byte

 

 

2nd byte

3rd byte

 

Time

 

 

 

RXD

 

 

0AH

 

 

0AH

0AH

 

0AH

The setting details for the first to the third bytes are shown below.

1st byte

 

2nd byte

 

BIT

When the bit is “1”

BIT

When the bit is “1”

0

Repeat recording function ON

0

Unused

1

Unused

1

Alarm recording function ON

2

POWER ON REC mode ON

2

Unused

3

Auto rewind ON

3

Sensor recording function ON

4

Unused

4

External recording function ON

5

Series recording function ON

5

Unused

6

Tape end buzzer ON during recording

6

Unused

7

Alarm recording buzzer ON

7

Warning buzzer ON

3rd byte

 

 

 

BIT

When the bit is “1”

 

 

0Unused

1Summer time compensation ON

2Unused

3Unused

4Unused

5Auto record check function ON

6Unused

7Unused

confirmation from the VCR after each transmission.

5On-screen setting command

(1)

ON SCREEN ON (70H)

: Activates on-screen indication.

 

ON SCREEN OFF (71H)

: Deactivates on-screen indication.

Setting procedure for the following command (2) is the same as when using the VCR controls. Be sure to transmit commands 1 byte at a

time with “ACK” (0AH) confirmation from the VCR after each transmission.

(2)ON SCREEN SELECT (74H): Switches the on-screen display items.

POS V+ (73H): Moves the on-screen indication in the vertical direction.

POS H+ (75H): Moves the on-screen indication in the horizontal direction.

5Other commands

(1)

AL/PL RESET (E1H)

: When transmitted during alarm recording, the recording mode switches back to the previous mode.

 

 

The VCR’s “AL” indication goes off. Transmit again after “AL” indicator goes off to reset the alarm/

(2)

COUNT RESET (E2H)

power loss memory.

: Resets the tape counter to “0000”.

59 (E)

60

Page 36
Image 36
JVC SR-9080 Date SET 8EH, Time SET 8FH, PRG/CLK 62H, Cancel 67H, On Screen on 70H, On Screen OFF 71H, AL/PL Reset E1H