10 APPENDIXES

10-2 Rear Panel’s Input/Output

10 APPENDIXES : U model

10-3 Specifications

Terminals

Signal levels

Remarks

5 Recording system

Luminance: FM recording Color: down-converted direct

[Time/date]

 

5 Display

Month, day, year, hours, minutes,

CAM SW OUT Camera switching signal output

ALARM IN Alarm signal input

During

 

 

 

 

 

 

(Timelapse recording)

recording

 

 

 

 

 

 

1 field

 

 

 

 

 

 

 

 

During

 

 

 

 

 

 

 

 

 

standby

 

 

 

 

 

 

 

 

 

GND

 

 

 

 

 

 

5m sec

 

Time

 

 

 

 

 

 

 

Camera switching signal output

 

 

 

 

 

 

 

The switching interval can be set to“1 field” or “1 frame”with the <CAMERA SW> in the <IN/OUT> setting screen. (With the menu switch set to “1 field”)

HV: 5 V

Open-collector output

Input at ground level

5 Signal system

(U model)

5 Signal system

(E model)

5 Tape speed

(U model)

5 Tape speed

recording NTSC-type color signal, EIA monochrome signal, 525 lines/ 60 fields PAL-type colour signal, CCIR monochrome signal, 625 lines/ 50 fields

33.35mm/sec., Standard (2H) mode

11.12mm/sec., Extended (6H) mode

23.39mm/sec., Standard mode (3H)

 

seconds, recording mode, alarm

 

input data, power loss data

5 Display position

Variable

5 Character size

16H

5Power backup Approx. two years (may be less depending on the operating environment)

[Alarm]

ALARM RST IN Alarm signal reset input

ALARM REC OUT Alarm recording mode signal output

TAPE END OUT Tape end signal output

WARNING OUT Warning signal output

CLOCK RESET IN Clock reset input

 

 

 

 

 

 

 

 

 

 

 

Min. 400 msec.

 

LV: 0 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HV: 5 V ~ 12 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min. 400 msec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HV:12 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(output impedance: 4.7 kohms)

 

 

 

 

 

 

 

 

 

 

 

Alarm

 

 

 

 

 

 

Record mode:

 

 

 

 

 

 

Record mode

 

 

 

 

 

 

 

 

 

 

 

 

 

Record mode:

 

repeat recording ON/auto rewind ON

repeat recording OFF/auto rewind OFF

 

 

 

 

 

 

 

 

 

 

 

HV: 12 V

 

 

 

 

 

 

 

 

 

 

 

 

LV: 0 V

 

 

 

 

 

 

 

 

 

About 2

 

Max.

10 mA

 

Tape end

 

Manual

 

 

 

seconds

 

 

 

 

 

 

 

 

 

operation

 

 

 

 

 

 

 

 

 

 

 

 

 

HV: 12 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(output impedance: 4.7 kohms)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning

 

 

Warning reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HV: 5 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LV: 0 V

 

Input at high level

Output at high level

Output at ground level

Output at high level

Input at ground level

(E model)

5 Recording and

playback time

(with T-120

cassette)

(U model)

5 Recording and

playback time

(with E-180

cassette) (E model)

5 Fast-forward/ rewind time

5 Power supply

5 Power consumption 5 Dimensions 5 Weight 5 Operating temperature 5 Operating humidity 5 Storage temperature

2 hours (Standard (2H) mode) 6 hours (Extended (6H) mode), L12, L18, L24, 24, 48, 72, 120, 168, 240, 480, 960 hours (including the HDR recording/playback mode) (Timelapse mode: field recording) 3 hours (Standard (3H) mode) L12, L24, 48, 72, 120, 168, 240, 480, 960 hours (Timelapse mode: field recording) Within about 4 minutes (with T-120 : U model, E-180 : E model cassette) AC 120 V, 50/60 Hz : U model AC 220 – 240 V, 50/60 Hz : E model 19 watts

360 (W) x 115 (H) x 372 (D) mm Approx. 5.5 kg 5°C — 40°C

30%RH or more, 80%RH or less –20°C — 60°C

5 Alarm input

Input at ground level

5Camera switching Negative pulse output (5 msec.)

output

Open-collector output

5 Accessory

Power cord x 1

Outer dimensions

 

 

 

 

 

 

 

 

 

 

 

362

372

360

REC

113

115

About 100 msec.

[Video System]

2

CLOCK RESET OUT Clock reset output

LV: 0 V About 100 msec.

Output at ground level

5Signal input 1.0 Vp-p, 75 ohms, unbalanced BNC

5Signal output Signal output 1.0 Vp-p, 75 ohms, unbalanced BNC

5 Horizontal

300 lines or more

resolution

 

Unit: mm

SERIES REC IN Series recording signal input

SERIES REC OUT Series recording signal output

SERIES REC IN External automatic recording signal input

2.5 - 3 sec.

2.5 - 3 sec.

External recording Min. 400 msec.

HV: 5 V

LV: 0 V

HV: 5 V

LV: 0 V

HV: 5 V

Input at ground level

Output at ground level

Input at ground level

5 Video S/N

43 dB or more (2H mode : U model, 3H

 

: E model)

[Audio system]

 

 

5 Number of tracks

1 (normal)

* Design and specifications subject to change without

5 Line input

–8 dBs, 50 kohms, unbalanced RCA

notice.

5 Mic input

–67 dBs, 600 ohms, unbalanced

 

5 Line output

–8 dBs, 1 kohm, unbalanced RCA

 

5 Frequency

100 Hz — 10 kHz (2H : U model, 3H : E

 

response

model mode)

 

5 Audio S/N

40 dB or more (2H : U model, 3H : E

 

 

model mode at 4% distortion level)

 

5Wow and flutter 0.15% WRMS or less (2H mode) : U model

0.20% WRMS or less (3H mode) : E model

65

66

Page 40
Image 40
JVC SR-9080 appendix Appendixes, Rear Panel’s Input/Output, Specifications