8
1
TO CAMERA
TO CAMERA
DATA I / O
DATA I / O
RX+RX
-
TX+TX
-
COM
1 2 3 4 5 6 7 8
COM
9/110/211/3 12/4 13/5 14/6 15/716/8
COM COM COM
CAMERA
CAMERA
SW
UNIT
UNIT
ALARM
ALARM
AUTO
AUTO
4312 8756
2 3 4 5 6 7 8
1
MONITOR
MONITOR
OUTPUT
OUTPUT
MONITOR
MONITOR
SERIAL-2
SERIAL-2
SERIAL-1
VIDEO INPUT
VIDEO INPUT
VIDEO OUTPUT
VIDEO OUTPUT
OUTPUT
OUTPUT
2
1
ON
ON
2 3 4 5 6 7 8
POWER
OFF
ON
AC INPUT
MONITOR
OUTPUT 1
TO
CAMERA
Remote control unit
RM-P2580
Control signal cable
Coaxial cable
AC 24 V
power supply
AC 24 V
power supply
AC 24 V
power supply
Monitor
Camera 1
Camera 2
Camera 8
TK-C655
TK-C655
TK-C655
MACHINE ID: 01
Switch 8: OFF
(RX TERM)
MACHINE ID: 02
Switch 8: OFF
(RX TERM)
MACHINE ID: 08
Switch 8: ON
(RX TERM)
Connections & Installation
TX +A
TX B
RX +C
RX D
TX +
Camera 1
CONTROL terminals
Camera 2
CONTROL
terminals
Camera 3
CONTROL
terminals
RX +
A
RX
B
TX +
C
TX
D
RM-P2580
terminal
A
TX B
RX +C
RX D
TX +A
TX B
RX +C
RX D
Connection of the control signal cable
(A twisted pair cable is recommended.)
Power cable
Control signal cable
To AC 24V power supply
To the TO CAMERA connector of the
RM-P2580 and to the next camera
Coaxial cable
To the VIDEO INPUT connector
of the RM-P2580
Duplex display ID No. display
LPROCESS<<>>I INTIA
:--I--PAN :--I--TILT
DUPLEX ID-01ROT>P COOL
Camera 1 monitor display
at power ON
(ID check procedure P. 13)
Switch 1
:
Switch 2
:
Switch 4 : ON
Switch 5 : OFF
Switch 7 : Invalid (Set to OFF)
Switch 8 :
Figure of 1
Figure of 10
Set it to the same number as the
VIDEO INPUT terminal of the RM-
P2580.
(Example) Camera 1:
Set the figure of 10 to “0” and
figure of 1 to “1”.
Set to ON only for the
camera connected at
the end of the control
signal cable.
Set to OFF for all
other cameras.
Machine ID
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
1
2
3
4
6
7
8
5
O
F
F
Invalid (Set to OFF.)
A Multi-Drop Communication System
A system that employs the RM-P2580 as the controller
The following figure shows a system that can accommodate up to eight cameras. (64 positions can be preset per camera.)
Observe the following points when connecting compo-
nents together:
•Turn all the components off before proceeding.
Read the instruction manuals of all components before pro-
ceeding.
•For the types and lengths of connection cables, see “Cable
Connections” on page 14.
Do not connect the control signal cables in a loop.
Cable connections P. 14
(Connector side of Ceiling Mount)
Switch settings P. 12
(Setting switches on the Ceiling Mount: Setting switch side)
Each terminal on the camera and the RM-
P2580 is marked A
, B
, C
or D
. In order
to facilitate understanding and to avoid
connection mistakes, it is recommended
to connect the terminals carrying the
same marks.