9
VIDEO
SWITCHER, etc.
CONTROLLER*
Length of stub
Length of stub
CONTROL Cable
CAM1 CAM2 CAM31 CAM32
PROTOCOL(1) : ON
MACHINE ID : 01
RX TERM : ON
PROTOCOL(1) : ON
MACHINE ID : 02
RX TERM : OFF
PROTOCOL(1) : ON
MACHINE ID : 31
RX TERM : OFF
PROTOCOL(1) : ON
MACHINE ID : 32
RX TERM : ON
Length of stub
VIDEO
SWITCHER, etc.
CONTROLLER*
Length of stub
CONTROL Cable
PROTOCOL(1) : ON
MACHINE ID : 01
RX TERM : ON
PROTOCOL(1) : ON
MACHINE ID : 02
RX TERM : OFF
PROTOCOL(1) : ON
MACHINE ID : 32
RX TERM : OFF
Length of stub
CAM1 CAM2 CAM32
Terminate it
with 110 .
Set the TERM switches of the cameras at each end
(CAM1 and CAM32) to ON, and the TERM switches of
the other cameras to OFF.
Do not terminate at the controller.
Set the TERM switch of CAM1 to ON, and terminate at the controller
with a resistance of 110 .
Set the TERM switches of the other cameras to OFF.
When the controller is located at the end of the system cable.
(An AC 24V power source must be supplied to each camera)
When the controller is located in the middle of the system cable.
(An AC 24V power source must be supplied to each camera)
Be sure to terminate the control signal cable at both ends. The cables (length of stub) connecting pieces of non-terminated
equipment (cameras or controllers) must be as short as possible. If the length of stub is too long, the precision of the control may
suffer.
MEMO
A system that does not employ the RM-P2580 as the controller