Kingston Technology MC133PD manual Interpreting the Results

Models: MC133PD

1 58
Download 58 pages 42.49 Kb
Page 40
Image 40

34

Appendix C Troubleshooting

Interpreting the Results

If the board fails the EEPROM test, try reprogramming the EEPROM using the EPROM.EXE program supplied with the MCMaster option disk. If you do this, and the test still fails, contact your dealer or Kingston Technical Support for further assistance.

If the POS Register test fails, the MCMaster is for some reason not supplying the correct ID to the Micro Channel bus. You can try inserting the MCMaster into another slot if one is available.

If this fails, inspect the card-edge connector for contamination and clean it if necessary. The easiest way to do this is by gently rubbing the contacts with a pink eraser until they are restored to a shiny gold color. Several commercial cleaners are also available specifically for cleaning gold contacts.

If neither of these actions corrects the problem, contact your dealer or Kingston Technical Support.

If one of the Memory Tests fails, try replacing one or both installed memory modules. If one SIMM is defective and the other is not, you'll be able to determine which by a process of elimination. Remember if you go through the swapping process that a single SIMM has to go into the slot closest to the planar board.

If any of the other tests fail, something on the board has malfunctioned that probably cannot be corrected in the field. Contact your dealer or Kingston Technical Support for information on getting the board repaired.

Kingston Technology Company

MCMaster User’s Guide - Rev. B06

Page 40
Image 40