Chapter 4: Rear Panel

Mains input

Always replace the mains fuse with one of the same type and rating, as printed underneath the fuse drawer.

The mains input section has a mains IEC socket, mains fuse compartment and on/off switch. Printed underneath is the mains supply voltage and fuse specifications.

The mains input is an auto-voltage sensing switch mode power supply that operates where normal mains voltage is in the range 100V AC to 240V AC.

Mains IEC socket

Mains fuse compartment Mains on/off switch

Supply voltage and fuse information

Clock section

This section provides 75 ohm connections for two types of external clock for synchronisation:

BLACK BURST 75R A single INPUT socket provides connection for a video signal generator.

WORD CLOCK 75R An OUTPUT socket and an INPUT socket provide connection for an external word clock source.

BNC chassis connectors

AES50 section (DN9650 only)

The AES50 section of the DN9650 has three EtherCon® XLR chassis connectors for audio connections to/from a Midas digital system or AES-equipped device.

Each connector supports 24 bi-directional channels operating at a fixed sampling frequency of 96kHz for compatibility with existing Midas and Klark Teknik AES50-equipped products.

EtherCon® XLR connectors

CONTROL connector

A single EtherCon® XLR chassis connector lets you connect to a computer to enable unit configuration and software upgrade.

 