Binarization the following descriptions are for binary images only.
The following binarization options work on grayscale scanned images and outputs a
Available binarization options are:
•iThresholding: selecting iThresholding allows the scanner to dynamically evaluate each document to determine the optimal threshold value to produce the highest quality image. This allows scanning of mixed document sets with varying quality (i.e., faint text, shaded backgrounds, color backgrounds) to be scanned using a single setting thus reducing the need for document sorting.
When using iThresholding, only Contrast may be adjusted.
•Fixed Processing (FP): used for
•Adaptive Thresholding (ATP): the Adaptive Threshold Processor separates the foreground information in an image (i.e., text, graphics, lines, etc.) from the background information (i.e., white or
When using Adaptive Thresholding, Threshold and Contrast may be adjusted. Contrast values may range from 1 to 100. A Contrast value of 100 is considered fully adaptive thresholding.
Fixed thresholding ATP disabled | ATP enabled |
Dithering a method used to simulate gray levels. When selected, the Dithering options are available.
•