Kodak RP 30 manual Preparing Replenisher, Tank Temperature ºC

Models: RP 30

1 235
Download 235 pages 61.19 Kb
Page 66
Image 66

Chemicals

Installing the Racks and Bringing the Tank Solutions to Temperature

When you fill the tanks with the new mixes, they will appear only partially filled. When you reinstall the racks in the tanks, the racks will displace more solution volume to fill the tanks.

1.Install each rack by slowly lowering it into the tank; the rack will displace additional volume to fill the tank and partially mix the solution.

2.When you have reinstalled all the racks, verify that all tanks are filled with solution.

3.Restore power to the equipment.

4.Starting the recirculation pumps will complete the mixing of the solutions.

5.Let the processor come up to operating temperature.

Tank

Temperature ºC

 

 

 

Developer

40.0

+/- 0.3

 

 

 

Bleach-Fix

38

+/- 2

 

 

 

Stabilizer

37

+/- 3

 

 

 

Preparing Replenisher

1.Fill 7 L (1.8 gal) of water in the Astor tank (1).

2.Fill the water tank until the upper one of the two float sensors is activated or the overflow indicator sticks out of the tank.

3.Prior to the first paper transport, water must be used to wet the foam rollers of the squeegee unit (2). Otherwise the wet paper could stick to the dry rollers.

2 1

KODAK PROFESSIONAL RP 30 Laser Printer

3-7

Page 66
Image 66
Kodak RP 30 manual Preparing Replenisher, Tank Temperature ºC