Bond in accordance with national and local codes. Open bonding lugs are located at the top of the junction box.

120/240 VAC Source

Check Valve

Blower Motor Cord

Control

Power Supply

Control

External Power

N

L1

L2

 

 

Typical Wiring Connection for North America

 

 

Breaker Box

 

 

 

 

 

* Connections to be Made

 

 

 

Typical Two-Pole

 

 

 

at the Circuit Breaker

 

 

 

Circuit Breaker

 

 

 

 

 

 

 

 

 

 

 

with GFCI

*L2

 

 

 

Wire Connector

 

 

 

 

Control Power

 

 

 

240 V

 

 

 

Junction Box

Ground

 

 

 

*L1

 

120 V

 

 

 

 

 

 

 

 

(Green with

 

120 V

 

No Connection

 

 

Yellow Stripes)

 

 

Blue (L1)

 

 

 

240 V

(Load Neutral)

 

 

 

 

 

* Line Neutral

 

 

 

 

From Control

 

 

(White

 

 

 

 

 

 

 

 

 

 

 

 

 

Curly Wire)

 

 

 

 

Brown (L2)

 

 

 

 

 

 

 

Neutral Bus

 

* Equipment Ground

Field Wiring

 

Wire Connectors

 

 

(From Junction Box

Electrician to provide

(In Breaker Box)

 

 

to GFCI Breaker)

suitable strain relief.

3. Make Electrical Connections - Standard

NOTE: The product model number is printed on a label on the blower side of the bath. This label also identifies the electrical rating of the product. All baths come equipped with a wiring junction box and are designed to operate between 220 V and 240 V at either 50 Hz or 60 Hz.

WARNING: Risk of electrical shock. Make sure the power has been disconnected before performing the following procedures.

WARNING: Risk of electrical shock. Connect the blower to a properly grounded Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). This will provide additional protection against line-to-ground shock hazard. A 220-240 V, 20 A, 50/60 Hz dedicated circuit is required.

IMPORTANT! The load neutral is not used. There should be no connection to the load neutral terminal on the Ground-Fault Circuit-Interrupter (GFCI) breaker. The green wire with the yellow stripe is the equipment ground and needs to be connected to the neutral bus in the main circuit breaker box.

NOTE: The wiring harness includes an antenna for the optional remote control. Do not alter or damage this antenna during installation.

Connect service to the junction box. The junction box contains blue, brown, and green with a yellow stripe colored wires and a ground lug

Follow local electrical codes. Bond in accordance with national and local codes.