TP-6810 11/1342 Section3 RDC2ControllerOperation
3.17.2 Networking ConfigurationSubmenu (OnCue Password)
The networking Configuration menu includes settings
used for communication with the KohlerrOnCuer
Home Generator Management System.
For most applications, DHCP is enabled and the IP
settingscannot be changed from the controller keypad.
If DHCP is enabled, IP parameters are not displayed.
If DHCP is disabled (i.e., if a static IP address is
required),then the IP parameters can be modified. For
applicationsthat require static IP addresses, press and
hold the select button to enable editing, disable DHCP,
and then step to the next parameters and enter the
information.
If an error occurs while setting a parameter, an error
message is displayed and then the controller exits the
edit mode. Previoussettings are preserved.
OnCue Password
Forthe initial OnCue setup, you will be required to reset
theOnCue password on the RDC2 controller, and then
enterit into the OnCue software. Toresetthe password,
follow the instructions in Figure 3-19.
Note: The password is displayed for only 10 seconds.
Be sure to write down the password and serial
number.
A new password is generated each time the reset
password procedure is performed. If the password is
reset after the OnCue system has been set up, the
connection will be lost. Enter the new password in
OnCue to reconnect.
tp6804
<----Return
DHCP:
Enabled
Reset OnCue
Password
Reset OnCue
Password? No
S/N: 1234567
New PW: 12345
PressSelect to enter YES
orNO as displayed. New
passwordis displayed for
approximately10 seconds.
Networking
Configuration
HOLD
Reset OnCue
Password? Yes
UParrow for YES,
Downarrow for NO.
Networking---->
Information
Networking---->
Status
Figure 3-19 Network Configuration Submenu