kg/cm2

kilograms per square

 

centimeter

kgm

kilogram-meter

kg/m3

kilograms per cubic meter

kHz

kilohertz

kJ

kilojoule

km

kilometer

kOhm, kΩ kilo-ohm

kPa

kilopascal

kph

kilometers per hour

kV

kilovolt

kVA

kilovolt ampere

kVAR

kilovolt ampere reactive

kW

kilowatt

kWh

kilowatt-hour

kWm

kilowatt mechanical

kWth

kilowatt-thermal

L

liter

LAN

local area network

L x W x H

length by width by height

lb.

pound, pounds

lbm/ft3

pounds mass per cubic feet

LCB

line circuit breaker

LCD

liquid crystal display

LED

light emitting diode

Lph

liters per hour

Lpm

liters per minute

LOP

low oil pressure

LP

liquefied petroleum

LPG

liquefied petroleum gas

LS

left side

Lwa

sound power level, A weighted

LWL

low water level

LWT

low water temperature

m

meter, milli (1/1000)

Mmega (106 when used with SI units), male

m3

cubic meter

m3/hr.

cubic meters per hour

m3/min.

cubic meters per minute

mA

milliampere

man.

manual

max.

maximum

MB

megabyte (220 bytes)

MCCB

molded-case circuit breaker

MCM

one thousand circular mils

meggar

megohmmeter

MHz

megahertz

mi.

mile

mil

one one-thousandth of an inch

min.

minimum, minute

misc.

miscellaneous

MJ

megajoule

mJ

millijoule

mmmillimeter

mOhm, mΩmilliohm MOhm, MΩmegohm

MOV

metal oxide varistor

MPa

megapascal

mpg

miles per gallon

mph

miles per hour

MS

military standard

ms

millisecond

m/sec.

meters per second

mtg.

mounting

MTU

Motoren-und Turbinen-Union

MW

megawatt

mW

milliwatt

μF

microfarad

N, norm.

normal (power source)

NA

not available, not applicable

nat. gas

natural gas

NBS

National Bureau of Standards

NC

normally closed

NEC

National Electrical Code

NEMA

National Electrical

 

Manufacturers Association

NFPA

National Fire Protection

 

Association

Nm

newton meter

NO

normally open

no., nos.

number, numbers

NPS

National Pipe, Straight

NPSC

National Pipe, Straight-coupling

NPT

National Standard taper pipe

 

thread per general use

NPTF

National Pipe, Taper-Fine

NR

not required, normal relay

ns

nanosecond

OC

overcrank

OD

outside diameter

OEM

original equipment

 

manufacturer

OF

overfrequency

opt.

option, optional

OS

oversize, overspeed

OSHA

Occupational Safety and Health

 

Administration

OV

overvoltage

oz.

ounce

p., pp.

page, pages

PC

personal computer

PCB

printed circuit board

pF

picofarad

PF

power factor

ph.,

phase

PHC

Phillipsr head Crimptiter

 

(screw)

PHH

Phillipsr hex head (screw)

PHM

pan head machine (screw)

PLC

programmable logic control

PMG

permanent magnet generator

pot

potentiometer, potential

ppm

parts per million

PROM

programmable read-only

 

memory

psi

pounds per square inch

psig

pounds per square inch gauge

pt.

pint

PTC

positive temperature coefficient

PTO

power takeoff

PVC

polyvinyl chloride

qt.

quart, quarts

qty.

quantity

Rreplacement (emergency) power source

rad.

radiator, radius

RAM

random access memory

RBUS

RS-485 proprietary

 

communications

RDO

relay driver output

ref.

reference

rem.

remote

Res/Coml

Residential/Commercial

RFI

radio frequency interference

RH

round head

RHM

round head machine (screw)

rly.

relay

rms

root mean square

rnd.

round

RO

read only

ROM

read only memory

rot.

rotate, rotating

rpm

revolutions per minute

RS

right side

RTDs

Resistance Temperature

 

Detectors

RTU

remote terminal unit

RTV

room temperature vulcanization

RW

read/write

SAE

Society of Automotive

 

Engineers

scfm

standard cubic feet per minute

SCR

silicon controlled rectifier

s, sec.

second

SI

Systeme international d’unites,

 

International System of Units

SI/EO

side in/end out

sil.

silencer

SMTP

simple mail transfer protocol

SN

serial number

SNMP

simple network management

 

protocol

SPDT

single-pole, double-throw

SPST

single-pole, single-throw

spec

specification

specs

specification(s)

sq.

square

sq. cm

square centimeter

sq. in.

square inch

SMS

short message service

SSstainless steel

std. standard

stl. steel

tach. tachometer

TB

terminal block

TCP

transmission control protocol

TD

time delay

TDC

top dead center

TDEC

time delay engine cooldown

TDEN

time delay emergency to

 

normal

TDES

time delay engine start

TDNE

time delay normal to

 

emergency

TDOE

time delay off to emergency

TDON

time delay off to normal

temp.

temperature

term.

terminal

THD

total harmonic distortion

TIF

telephone influence factor

tol.

tolerance

turbo.

turbocharger

typ.

typical (same in multiple

 

locations)

UF

underfrequency

UHF

ultrahigh frequency

UIF

user interface

UL

Underwriter’s Laboratories, Inc.

UNC

unified coarse thread (was NC)

UNF

unified fine thread (was NF)

univ.

universal

URL

uniform resource locator

 

(web address)

US

undersize, underspeed

UV

ultraviolet, undervoltage

V

volt

VAC

volts alternating current

VAR

voltampere reactive

VDC

volts direct current

VFD

vacuum fluorescent display

VGA

video graphics adapter

VHF

very high frequency

W

watt

WCR

withstand and closing rating

w/

with

WO

write only

w/o

without

wt.

weight

xfmr

transformer

62 Appendix

TP-6810 11/13

Page 62
Image 62
Kohler 60RCL, 38RCL, 48RCL manual Lcb

38RCL, 48RCL, 60RCL specifications

The Kohler RCL series of generators, particularly the 60RCL, 48RCL, and 38RCL models, represents a premium choice for those seeking reliable power solutions for residential and light commercial applications. Each model is tailored to meet diverse power needs, ensuring uninterrupted electricity supply during outages.

The 60RCL is engineered for maximum performance, offering 60 kW of power. This model is ideal for larger homes or small businesses that require dependable backup power. Its powerful Kohler engine is designed to deliver a quiet, smooth performance, while the advanced sound-dampening features keep noise levels to a minimum. The 48RCL offers a slightly lower output at 48 kW, making it suitable for medium-sized homes. Its compact design allows for flexible installation options, whether it’s outdoors or in a utility area, while still providing robust power during critical times.

The 38RCL, while the smallest of the series with 38 kW output, is perfect for homes that need a reliable backup generator without the bulk. Its streamlined design does not compromise on performance, making it an excellent choice for energy-efficient homes. All models in the RCL series come equipped with Kohler's Command Pro commercial-grade engine, ensuring longevity and reliability even in the harshest conditions.

A standout feature of the RCL series is the integrated KOHLER® 2.4-inch color display, which allows users to monitor generator performance in real-time. This user-friendly interface provides vital information such as operational status, run time, and maintenance notifications. Additionally, the series is designed with automatic transfer switches that allow for seamless switching between utility and generator power.

Moreover, these generators incorporate advanced control systems with remote monitoring capabilities, enabling users to check the status of their power supply from a smartphone or tablet. Designed with efficiency in mind, the RCL series boasts a fuel-efficient operation that supports both natural gas and propane, catering to diverse energy preferences.

In summary, the Kohler 60RCL, 48RCL, and 38RCL generators combine high performance, advanced technology, and user-friendly features. They are reliable solutions for anyone looking to safeguard their power needs, ensuring peace of mind when it matters most.