A protocol is a set of rules the computer follows in sending data to the printer. The RS-232C/RS-422A parameters are stored in battery backed-up memory. They are indicated on the status printout. They can be changed by the FRPO (firmware reprogram) command described in the Programming Manual provided on the CD-ROM supplied with the printer. The parameters and their identification codes are given below.

H1: Baud rate

Parameter value

 

Baud rate

12

 

1200

 

 

 

24

 

2400

 

 

 

48

 

4800

 

 

 

96

 

9600

 

 

 

19

 

19200

 

 

 

38

 

38400

 

 

 

57

 

57600

 

 

 

11

 

115200

 

 

The factory setting is 9600 baud.

H2: Data bits

 

7 or 8, factory-set to 8.

 

H3: Stop bits

 

1 or 2, factory-set to 1.

 

H4: Parity

 

 

 

 

Parameter value

 

Meaning

0

 

None

 

 

 

1

 

Odd

 

 

 

2

 

Even

 

 

 

3

 

Ignore

 

 

 

The factory setting is “None” (0 on the status printout).