Lennox International Inc Lennox Merit Series Gas Furnace Upflow/Horizontal Air Discharge, ML193UH

Models: Lennox Merit Series Gas Furnace Upflow/Horizontal Air Discharge ML193UH

1 51
Download 51 pages 42.64 Kb
Page 11
Image 11
Optional Return Air Base

CONDENSATE

Optional Return Air Base

(Upflow Applications Only)

TRAP

 

AIR FLOW

17−1/2 (446) B Width (50W98)

21 (533) C Width (50W99) 24−1/2 (622) D Width (51W00)

FRONT VIEW

FURNACE

FRONT

INDOOR AIR

QUALITY

CABINET

(PCO, Filter

Cabinet, etc.)

OPTIONAL RETURN AIR BASE

IF BASE

3−1/4

 

 

1 23 (584)

 

 

 

 

IS USED

 

 

Overall

 

 

 

 

(83)

 

 

1

 

 

 

WITHOUT

 

 

(Maximum)

Minimum

 

 

 

 

 

 

 

 

IAQ CABINET,

 

 

 

 

 

11 (279)

 

 

A SINGLE

 

1 Unit side return air

2 Maximum

1

22−7/16

RETURN AIR

 

 

14 (356)

 

 

 

 

(570)

PLENUM

 

 

Opening

 

 

 

 

 

 

 

 

Overall

MUST

 

 

 

 

 

 

 

 

 

 

 

 

 

(Maximum)

COVER BOTH

 

 

 

 

 

 

UNIT AND

 

 

 

SIDE RETURN

 

 

RETURN

7−1/4

5−5/8

 

 

AIR BASE

AIR OPENINGS

 

 

(143)

 

 

 

OPENINGS

(184)

 

 

 

 

(Either Side)

 

 

 

 

 

 

 

 

 

 

 

 

23

 

 

 

3/4

 

 

 

 

(584)

 

 

 

 

 

 

 

26−7/8

 

 

 

(19)

 

 

 

 

 

 

 

 

 

 

 

 

(683)

 

 

 

 

SIDE VIEW

NOTE- Optional side return air filter kits are not for use with return air base.

1Both the unit return air opening and the base return air opening must be covered by a single plenum or IAQ cabinet.

Minimum unit side return air opening dimensions for units requiring 1800 cfm of air and over (W x H): 23 x 11 in. (584 x 279 mm). The opening can be cut as needed to accommodate plenum or IAQ cabinet while maintaining dimensions shown.

Side return air openings must be cut in the field. There are cutting guides stenciled on the cabinet for the side return air

opening. The size of the opening must not extend beyond the markings on the furnace cabinet.

2To minimize pressure drop, the largest opening height possible (up to 14 inches) is preferred.

FIGURE 14

Removing the Bottom Panel

Screw

Bottom Cap

Bottom Panel

FIGURE 15

Removing the Bottom Panel

Remove the two screws that secure the bottom cap to the furnace. Pivot the bottom cap down to release the bottom panel. Once the bottom panel has been removed, reinstall the bottom cap. See figure 15.

Horizontal Applications

(Upflow Applications Only)WARNING

Do not install the furnace on its front or back. See figure 16.

FrontBack

FIGURE 16

Page 11

Page 11
Image 11
Lennox International Inc Lennox Merit Series Gas Furnace Upflow/Horizontal Air Discharge, ML193UH Horizontal Applications