The ring indicator (RI) is signaled by a serial device or a PC Card device. ( does not support the ring indicator (RI) resume by PC Card device.)

The time set on the resume timer elapses.

Note: The computer does not accept any input immediately after it enters sleep (standby) mode. Wait a few seconds before taking any action to reenter operation mode.

Hibernation mode

In hibernation mode, the following occurs:

The system status, RAM, VRAM, and setup data are stored on the hard disk.

The system is powered off.

To cause the computer to enter hibernation mode, do any of the following:

Press the Fn+F12 keys.

If you have defined one of the following actions as the event that causes the system to go into hibernation mode, perform that action.

Closing the lid.

Pressing the power button.

Pressing Fn+F4 keys.

Also, the computer goes into hibernation mode automatically in either of the following conditions:

If a “hibernation time” has been set on the timer, and if the user does not do any operation with the keyboard, the TrackPoint, the hard disk drive, the parallel connector, or the diskette drive within that time.

If the timer conditions are satisfied in suspend mode.

When the power is turned on, the computer returns from hibernation mode and resumes operation. The hibernation file in the boot record on the hard disk drive is read, and system status is restored from the hard disk drive.

Symptom-to-FRU index

This section contains following information:

“Numeric error codes” on page 41

“Error messages” on page 45

“Beep symptoms” on page 46

“No-beep symptoms” on page 47

“LCD-related symptoms” on page 47

“Intermittent problems” on page 48

“Undetermined problems” on page 48

The symptom-to-FRU index in this section lists symptoms and errors and their possible causes. The most likely cause is listed first, in boldface type.

Note: Do the FRU replacement or other actions in the sequence shown in the column headed “FRU or action, in sequence.” If replacing a FRU does not solve the problem, put the original part back in the computer. Do not replace a nondefective FRU.

This index can also help you determine, during regular servicing, what FRUs are likely to need to be replaced next.

40ThinkPad X200 Tablet and X201 Tablet Hardware Maintenance Manual

Page 48
Image 48
Lenovo 3093AC6 manual Hibernation mode, Symptom-to-FRU index