Table 2. Numeric error codes (continued)

Symptom or error

FRU or action, in sequence

 

 

1830

Install DIMM in Slot-0, but not in Slot-1.

Invalid memory configuration—Power off and install a

Note: For the construction of the DIMM slot, see “1040

memory module to Slot-0 or the lower slot.

DIMM” on page 67.

 

 

 

2000

1.

Undock docking station or port replicator if it is

Hard Drive Active Protection sensor diagnostics

 

attached to the ThinkPad Notebook.

failed.Press <Esc> to continue.Press <F1> to enter

2.

Place the ThinkPad Notebook on a horizontal surface.

SETUP

 

Do not apply any physical shock to the computer.

 

3.

Run Diagnostics >ThinkPad Devices >HDD Active

 

 

Protection Test.

 

 

2010

Inform the following information to the customer: If

Warning: Your internal hard disk drive (HDD) may not

in the primary bay the customer is using a non-IBM

function correctly on this system. Ensure that your HDD

or non-Lenovo hard disk drive (HDD), or an old

is supported on this system and that the latest HDD

generation IBM HDD which is not supported by this

firmware is installed.

system, with the risk in mind, the customer can still

 

use it by pressing ESC. If in the primary drive bay the

 

customer is using a supported IBM/Lenovo HDD with

 

an old firmware, the customer needs to update its

 

firmware to the latest. The latest version is available at

 

http://www.lenovo.com/support

 

 

201x

Inform the following information to the customer: If the

The solid state drive you have installed has not passed

customer is using a non qualified SSD which is not

qualification for use in this computer. Using this drive may

supported by this system, with the risk in mind, the

cause compatibility issues and potential issues with data

customer can still use it by pressing ESC. Location of the

integrity, including data loss. Press <Esc> to continue.

SSD is designated as below:

 

 

2010: HDD0 (in HDD slot-0)

 

 

2011: HDD1 (in HDD slot-1)

 

 

2012: Ultrabay with HDD adapter

 

 

 

2100

1.

Reseat the hard disk drive.

Initialization error on HDD0 (Main hard disk drive)

2.

Main hard disk drive.

 

3.

System board.

 

 

 

2102

1.

Reseat the hard disk drive.

Initialization error on HDD1 (Ultrabay hard disk drive)

2.

Ultrabay™ hard disk drive.

 

3.

System board.

 

 

 

2110

1.

Reseat the hard disk drive.

Read error on HDD0 (Main hard disk drive)

2.

Main hard disk drive.

 

3.

System board.

 

 

 

2112

1.

Reseat the hard disk drive.

Read error on HDD1 (Ultrabay hard disk drive)

2.

Ultrabay hard disk drive.

 

3.

System board.

 

 

 

Error messages

Table 3. Error messages

Symptom or error

FRU or action, in sequence

 

 

 

Device address conflict.

1.

Load “Setup Defaults” in the BIOS Setup Utility.

 

2.

Backup battery.

 

3.

System board.

 

 

 

Allocation error for device.

1.

Load “Setup Defaults” in the BIOS Setup Utility.

 

2.

Backup battery.

 

3.

System board.

 

 

 

Chapter 4. Related service information 45

Page 53
Image 53
Lenovo 3093AC6 manual Error messages