Table 2. Numeric error codes (continued)
Symptom or error | FRU or action, in sequence | |
|
| |
1830 | Install DIMM in | |
Invalid memory | Note: For the construction of the DIMM slot, see “1040 | |
memory module to | DIMM” on page 67. | |
|
|
|
2000 | 1. | Undock docking station or port replicator if it is |
Hard Drive Active Protection sensor diagnostics |
| attached to the ThinkPad Notebook. |
failed.Press <Esc> to continue.Press <F1> to enter | 2. | Place the ThinkPad Notebook on a horizontal surface. |
SETUP |
| Do not apply any physical shock to the computer. |
| 3. | Run Diagnostics >ThinkPad Devices >HDD Active |
|
| Protection Test. |
|
| |
2010 | Inform the following information to the customer: If | |
Warning: Your internal hard disk drive (HDD) may not | in the primary bay the customer is using a | |
function correctly on this system. Ensure that your HDD | or | |
is supported on this system and that the latest HDD | generation IBM HDD which is not supported by this | |
firmware is installed. | system, with the risk in mind, the customer can still | |
| use it by pressing ESC. If in the primary drive bay the | |
| customer is using a supported IBM/Lenovo HDD with | |
| an old firmware, the customer needs to update its | |
| firmware to the latest. The latest version is available at | |
| http://www.lenovo.com/support | |
|
| |
201x | Inform the following information to the customer: If the | |
The solid state drive you have installed has not passed | customer is using a non qualified SSD which is not | |
qualification for use in this computer. Using this drive may | supported by this system, with the risk in mind, the | |
cause compatibility issues and potential issues with data | customer can still use it by pressing ESC. Location of the | |
integrity, including data loss. Press <Esc> to continue. | SSD is designated as below: | |
|
| 2010: HDD0 (in HDD |
|
| 2011: HDD1 (in HDD |
|
| 2012: Ultrabay with HDD adapter |
|
|
|
2100 | 1. | Reseat the hard disk drive. |
Initialization error on HDD0 (Main hard disk drive) | 2. | Main hard disk drive. |
| 3. | System board. |
|
|
|
2102 | 1. | Reseat the hard disk drive. |
Initialization error on HDD1 (Ultrabay hard disk drive) | 2. | Ultrabay™ hard disk drive. |
| 3. | System board. |
|
|
|
2110 | 1. | Reseat the hard disk drive. |
Read error on HDD0 (Main hard disk drive) | 2. | Main hard disk drive. |
| 3. | System board. |
|
|
|
2112 | 1. | Reseat the hard disk drive. |
Read error on HDD1 (Ultrabay hard disk drive) | 2. | Ultrabay hard disk drive. |
| 3. | System board. |
|
|
|
Error messages
Table 3. Error messages
Symptom or error | FRU or action, in sequence | |
|
|
|
Device address conflict. | 1. | Load “Setup Defaults” in the BIOS Setup Utility. |
| 2. | Backup battery. |
| 3. | System board. |
|
|
|
Allocation error for device. | 1. | Load “Setup Defaults” in the BIOS Setup Utility. |
| 2. | Backup battery. |
| 3. | System board. |
|
|
|
Chapter 4. Related service information 45