Diagnostic Error Code

FRU/Action

 

 

 

018-196-XXX

1.

Press F3 to review the log file

PCI Card test halt, error threshold exceeded

2.

Re-start the test to reset the log file

 

 

 

 

018-197-XXX

1.

Make sure the component that is called

PCI Card test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 55

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

018-198-XXX

1.

If a component is called out, make sure

PCI Card test aborted

 

it is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 55

 

2.

Flash the system and re-test. See “Flash

 

 

update procedures” on page 214

 

3.

Go to “Undetermined problems” on page

 

 

90

 

 

 

018-199-XXX

1.

Go to “Undetermined problems” on page

PCI Card test failed, cause unknown

 

90

 

 

 

2.

Flash the system and re-test. See “Flash

 

 

update procedures” on page 214

 

3.

Replace component under function test

 

 

 

018-250-XXX

1.

PCI card

PCI Card Services error

2.

Riser card, if installed

 

 

3.

System board

 

 

020-000-XXX

No action

PCI Interface Test Passed

 

 

 

 

 

020-0XX-XXX

1.

PCI card

PCI Interface error

2.

Riser card, if installed

 

 

3.

System board

 

 

020-195-XXX

Information only

PCI Test aborted by user

Re-start the test, if necessary

 

 

 

020-196-XXX

1.

Press F3 to review the log file

PCI test halt, error threshold exceeded

2.

Re-start the test to reset the log file

 

 

 

 

020-197-XXX

1.

Make sure the component that is called

PCI test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 55

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

Chapter 7. Symptom-to-FRU Index 71

Page 77
Image 77
Lenovo 8085, 8177 XXX Make sure the component that is called, XXX If a component is called out, make sure, 018-199-XXX