Lenovo 8126, 8177, 8175 XXX Remove USB devices and re-test, XXX System board, XXX Information only

Models: 8148 8177 8149 8084 8178 8174 8085 8175 8126 8179 8176 8147

1 228
Download 228 pages 3.54 Kb
Page 76
Image 76

Diagnostic Error Code

FRU/Action

 

 

 

015-034-XXX

1.

Reboot the system

USB port buffer

2.

Flash the system and re-test. See “Flash

allocation failure

 

update procedures” on page 214

 

 

 

3.

Run memory test

 

4.

System board

 

 

 

015-035-XXX

1.

Remove USB device(s) and re-test

USB port Reset condition detected

2.

System board

 

 

 

015-036-XXX

System board

USB port Register error

 

 

 

 

 

015-040-XXX

1.

Run setup and check for conflicts

USB port IRQ failure

2.

Flash the system. See “Flash update

 

 

 

procedures” on page 214

 

3.

System board

 

 

015-195-XXX

Information only

USB port Test aborted by user

Re-start the test, if necessary

 

 

 

015-196-XXX

1.

Press F3 to review the log file

USB port test halt, error threshold exceeded

2.

Re-start the test to reset the log file

 

 

 

 

015-197-XXX

1.

Make sure the component that is called

USB port test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 55

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

015-198-XXX

1.

If a component is called out, make sure

USB port test aborted

 

it is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 55

 

2.

Flash the system and re-test. See “Flash

 

 

update procedures” on page 214

 

3.

Go to “Undetermined problems” on page

 

 

90

 

 

 

015-199-XXX

1.

Go to “Undetermined problems” on page

USB port test failed, cause unknown

 

90

 

 

 

2.

Flash the system and re-test. See “Flash

 

 

update procedures” on page 214

 

3.

Replace component under function test

 

 

018-000-XXX

No action

PCI Card Test Passed

 

 

 

 

 

018-0XX-XXX

1.

Riser card, if installed

PCI Card Failure

2.

System board

 

 

 

 

018-195-XXX

1.

PCI card

PCI Card Test aborted by user

2.

Information only

 

 

 

Re-start the test, if necessary

 

 

 

70Hardware Maintenance Manual

Page 76
Image 76
Lenovo 8126, 8177 XXX Remove USB devices and re-test, XXX System board, XXX Run setup and check for conflicts, 015-199-XXX