Lenovo 8176, 8177, 8175, 8084 Post Error Code FRU/Action, 201, 210, 211, 212, 250, 270, 271, 1762

Models: 8148 8177 8149 8084 8178 8174 8085 8175 8126 8179 8176 8147

1 228
Download 228 pages 3.54 Kb
Page 92
Image 92

POST Error Code

FRU/Action

 

 

191 System Security: Embedded Security

If problem persists, replace the system board

hardware Reset

 

 

 

 

192 System Security: Embedded Security

If problem persists, replace the system board

hardware tamper detected

 

 

 

 

193 System Security: Embedded Security

If problem persists, replace the system board

hardware Removed

 

 

 

 

194 System Security: Asset ID Antenna has

If problem persists, replace the system board

been Removed

 

 

 

 

195 System Security: Asset ID Antenna has

If problem persists, replace the system board

been installed

 

 

 

 

196 System Tampered Cleared

If problem persists, replace the system board

 

 

 

201

1.

Run Enhanced Diagnostics Memory Test

Memory error

2.

Memory module

 

 

3.

System board

 

 

 

210

1.

Check for stuck keys

Keyboard stuck key error

2.

Replace the keyboard

 

 

 

 

211

1.

Make sure keyboard is connected

Keyboard error

 

correctly

 

 

 

2.

Check for stuck keys

 

3.

Replace the keyboard

 

 

 

212

1.

Replace the keyboard

Keyboard controller error

2.

If problem persists, replace the system

 

 

 

board

 

 

 

250

1.

Replace the battery and run Setup

Battery is dead

2.

If problem persists, replace the system

 

 

 

board

 

 

 

270

1.

Run Setup and set date and time

Real time clock error

2.

If problem persists, replace the system

 

 

 

board

 

 

 

271

1.

Run Setup and set date and time

Date and time out of range

2.

If problem persists, replace the system

 

 

 

board

 

 

662 Configuration Change has occurred

Diskette drive configuration error or wrong

 

diskette drive type; run Setup.

 

 

 

1762

1.

Run Setup and verify hard disk drive

Configuration Change has occurred

 

settings.

 

 

 

2.

Run hard disk drive diagnostics.

 

3.

Replace hard disk drive

 

 

 

1800 PCI/PnP Error! No Hardware Interrupt

1.

Run Setup and verify PCI/ISA

Available

 

configuration settings.

 

 

 

2.

Run diagnostics.

 

3.

Replace PCI Adapter

 

 

 