4085-001

Cam System Motor/Sensor Service Check

 

FRU

Action

 

 

 

1

Motor does not

Check the voltage at connector (J8) on the engine

 

work.

board. At pins 1, 2, 3, and 4 with the power on.

 

Bat Wings do not

There should be approximately +34 V dc on each

 

move.

pin to ground. If the voltage is incorrect, replace

 

 

the engine board. If the voltage is correct,

 

 

disconnect (J8) and check between pins 2 and 4

 

 

on the connector for approximately 7.5 ohms. If

 

 

the reading is incorrect, check the continuity

 

 

between pins 2 and 4 to the motor case. If

 

 

continuity exists, replace the cam system motor.

 

 

To check the sensor, check connector (J8) at pin 5

 

 

for approximately +4.9 volts. If voltage is incorrect,

 

 

replace the engine board. If the voltage is correct,

 

 

disconnect (J8) from the engine board and check

 

 

for an ohm reading of 6.95 between pins 5 and 7.

 

 

If the reading is not correct, replace the sensor.

 

 

Note: If a short exists in the cam system motor,

 

 

damage to the engine board drivers and power

 

 

supply may occur.

 

 

 

User Error Messages

Message

Explanation

 

 

30 Cartridges Missing:

Press Go to clear the error. Supplies status

•

Color

appears on the display and the cartridge

missing shows in the supplies menus. This

•

Black

remains until the user accesses the Tests Menu

 

 

 

 

to install a cartridge and fill the empty slots.

 

 

 