4085-001
Diagnostics (Mode 2) - Supplies Tests
For each of the following four tests, the sequence of events is the same:
1.The printheads are uncapped when the test is invoked.
2.The printheads moves to the middle of the frame to give the servicer access to the printheads and tanks under test. The data corresponding to the test being run begins updating real time on the panel as described.
3.When the test is ended by pressing Return or Stop, the carrier is homed and the printheads are capped.
Ink Tank Memories
This test determines the status of the electrical connection to the ink tank memories. The status is indicated real time by either “+” (good) or
Ink Tank Mem Test
K=+ C=+ M=+ Y=+
To exit the test, select Return or Stop.
Printhead Memories
This test determines the status of the electrical connection to the printhead memories. The status is indicated real time by either “+” (good) or
Printhead Mem Test
K=+ CMY=+
To exit the test, select Return or Stop.