4085-001
Index Card/Sensor Service Check
| FRU | Action |
|
|
|
1 | Index motor does | If the index motor does not work, see “Index Motor |
| not work. | Service Check” on page |
|
| is working correctly see “Index System Test” on |
|
| page |
|
| encoder disk assembly. See “Encoder Disk Feed |
|
| Roller Assembly Removal” on page |
|
|
|
2 | Index Sensor | To check the sensor, see the “Index System Test” |
|
| on page |
|
|
|
Transport Service Check
Note: If the carrier strikes the left side frame and continues to drive into the frame, then see page
| FRU | Action |
|
|
|
1 | Transport Motor | Check the motor for binds, or loose motor pulley. |
|
| Disconnect the transport motor (J5) from the |
|
| engine board. Check for approximately 12 ohms |
|
| between pins 1 and 2 on the motor cable. If the |
|
| reading is incorrect, replace the motor. |
|
| Check for motor pins shorted to the motor |
|
| housing. If you find a pin shorted to the housing, |
|
| replace the motor. If the failure remains, replace |
|
| the engine board. |
|
|
|
2 | Maintenance | If access door switch does not work or carrier |
| Homing Sensor | does not move, see the “Maintenance Station |
|
| Service Checks” on page |
|
|
|
3 | Engine Board | Disconnect (J2) from the engine board and check |
|
| for approximately +29 V dc between |
|
| |
|
| board. |
|
|
|
4 | Carrier Guide | Clean the carrier rod. |
| Rod | Note: Lubricate the rod and the carrier rod |
|
| |
|
| bearing surface. Do not use excess lubricant. Take |
|
| care to protect the encoder strip from grease. |
|
|
|
Diagnostic Information