4085-001
Diagnostics (Mode 2) - Base Sensor Tests
Paper Path Sensors
This test determines if a group of sensors related to the paper path are working correctly. To run the test, select Paper Path Sensors from the BASE SENSOR TESTS menu. The following screen is displayed:
Paper Path
TC=C IS=C CO=C
Terminology:
•TC refers to the PerfectFinish path
•IS or Input Sensor refers to the input (grit roll) sensor.
•CO or Cover Open refers to the cover open sensor.
Once this screen is displayed, the sensor can be manually actuated. When the sensor is closed, C is displayed. When the sensor is open, O is displayed. If the wrong message is displayed, the sensor is malfunctioning.
TC or IS=O = Media Clear
TC or IS=C = Media Present
CO=O = Cover Open
CO=C = Cover Closed
To exit the test, select Return or Stop.
Supplies Sensors
This test is used to determine if a group of sensors related to the supplies are working correctly. To run the test, select Supplies Sensors from the BASE SENSOR TESTS menu. The following screen will be displayed:
Supplies Sensors
TP=O TF=C
Diagnostic Aids