Message | Explanation |
|
|
54 Parallel Error | An IEEE 1284 protocol error is detected on the |
| parallel host interface, or due to a faulty cable. |
| Once a host interface error has been displayed |
| for the first time, reporting of further host |
| interface errors for the associated port is |
| suppressed until the interface parameters are |
| changed, or the printer is powered off. |
| Press Go to clear the message and continue |
| processing the print job. The job may not print |
| correctly. Verify that the correct cable is used. If |
| a serial error has occurred, be sure the serial |
| interface parameters (protocol, baud, parity and |
| data bits) are set correctly on the printer and |
| the host computer. If a parallel error has |
| occurred, check the cable connection between |
| the host and printer. |
| Press Menu> or Menu< to access the reset |
| function in the Busy/Waiting Menu group. |
| Menu Lockout does not prevent access to the |
| Busy/Waiting Menu group. The menu buttons |
| are not active when Reset Control is Off. |
| Press and hold Select and then press Return |
| to determine the exact cause of host interface |
| error. |
| If a serial error has occurred, a |
| code displays in hexadecimal on the second |
| line of the LCD. If bit 15 is on, a framing error |
| has occurred. If bit 14 is on, an overrun error |
| has occurred. If bit 13 is on, a parity error has |
| occurred. |
|
|