Microprocessor problems
vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee Chapter 3, “Parts listing, ThinkServer TS100 Machine Types 6431, 6432, 6433, and 6434,” on page 37 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Symptom | Action | ||
|
|
| |
The server emits a continuous | 1. | Make sure that the microprocessor is supported on this server. | |
beep during POST, indicating | |||
2. | (Trained service technician only) Reseat the microprocessor. | ||
that the startup (boot) | |||
3. | Replace the following components one at a time, in the order shown, restarting | ||
microprocessor is not working | |||
correctly. |
| the server each time: | |
|
| a. (Trained service technician only) Microprocessor | |
|
| b. (Trained service technician only) System board | |
|
|
|
Monitor or video problems
Some Lenovo monitors have their own
vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee Chapter 3, “Parts listing, ThinkServer TS100 Machine Types 6431, 6432, 6433, and 6434,” on page 37 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Symptom | Action | |
|
|
|
Testing the monitor | 1. | Make sure that the monitor cables are firmly connected. |
| ||
| 2. | Try using a different monitor on the server, or try using the monitor that is being |
|
| tested on a different server. |
| 3. | Run the diagnostic programs. If the monitor passes the diagnostic programs, |
|
| the problem might be a video device driver. |
| 4. | Reseat the Remote Supervisor Adapter II SlimLine adapter (if one is installed). |
| 5. | Replace the Remote Supervisor Adapter II SlimLine adapter. |
| 6. | (Trained service technician only) Replace the system board. |
|
|
|
The screen is blank. | 1. | Make sure that: |
| ||
|
| v The server is turned on. If there is no power to the server, see “Power |
|
| problems” on page 156. |
|
| v The monitor cables are connected correctly. |
|
| v The monitor is turned on and the brightness and contrast controls are |
|
| adjusted correctly. |
|
| v A single beep sounds when the server is turned on, indicating the successful |
|
| completion of POST. |
| 2. | Make sure that the correct server is controlling the monitor, if applicable. |
| 3. | Make sure that damaged BIOS code is not affecting the video; see “Updating |
|
| |
| 4. | See “Solving undetermined problems” on page 245. |
|
|
|