Hardware Maintenance Manual
Page
Hardware Maintenance Manual
Page
Contents
Diagnostics
Post
Appendix A. Getting help and technical assistance
Page
Safety
Vii
Guidelines for trained service technicians
Inspecting for unsafe conditions
Guidelines for servicing electrical equipment
Safety statements
To Connect To Disconnect
Page
Safety
Statement
Safety
Page
Introduction
Related documentation
Page
Features and specifications
Features and specifications
Server controls, LEDs, and power
Power-on LED
Power-control button
Front view
USB connectors
CD-eject or DVD-eject button
CD or DVD drive activity LED
Optional diskette-eject button
Rear view
Turning off the server
Server power features
Turning on the server
Introduction
Connectors, LEDs, and jumpers
System board internal connectors
System board external connectors
System board optional-devices connectors
System board LEDs
Following illustration shows the LEDs on the system board
Jumper number Jumper name Jumper setting
System board jumpers
JP6
Page
Configuring the server
Configuration/Setup Utility program
Updating the firmware
EasyManage software
ThinkServer EasyUpdate program
Boot Menu program
Broadcom NetXtreme Gigabit Ethernet Boot Agent
LSI Configuration Utility program
Configuration/Setup Utility menu choices
Using the Configuration/Setup Utility program
Starting the Configuration/Setup Utility program
Parallel Port Setup
Administrator Password
Power-on Password
Serial Port
Advanced Setup
RSA II Settings
Baseboard Management Controller BMC Setting
Ipmi Specification Version
BMC Post Watchdog Timeout
BMC Serial Port Access Mode
Pre-Boot
Disabled
Using passwords
Save Settings
Restore Settings
Load Default Settings
Before you use the ThinkServer EasyStartup DVD
EasyStartup overview
Configuration information and instructions
Installing your operating system without using EasyStartup
Configuration information and instructions
Page
Serial over LAN Proxy
Using the Boot Menu program
Ipmi Intelligent Platform Management Interface Shell
Enabling the Broadcom NetXtreme Gigabit Ethernet Boot Agent
LSI Configuration Utility program
Starting the LSI Configuration Utility program
Formatting a hard disk drive
Setting up a Remote Supervisor Adapter II SlimLine
Requirements
Creating a RAID array of hard disk drives
Select RAID Properties
Cabling the Remote Supervisor Adapter II SlimLine
Ethernet transmit/ receive activity LED
Completing the setup
Page
Dimm
Replaceable server components
CRU part Number Optional FRU part Index Description
Hard disk drive, SATA, 3.5-inch 750 GB, 10K, hot-swap
Microprocessor, X3370 3.0G12MB models CTO
CRU part Number Optional FRU part Index Description
Frugbm all models
Front-panel assembly all models
Hard disk drive cage, 2.5-inch drives eight bays all
Power supply, non-redundant 401 watt models 17U 17F
Parts listing, Types
DVD-ROM drive, Sata 16/48 optional models 13U 13F
Microprocessor, E7200 2.53G3MB models CTO
Power supply, redundant, 430 watt optional models 14G
Parts listing, Types
Power cords
Emirates Dubai, United Kingdom, Yemen, Zambia, Zimbabwe
Yugoslavia Federal Republic of, Zaire models 17G 18G 19G
Power cords, Type
Yugoslavia Federal Republic of, Zaire models 13A 14A 15A
Power cords, Type
Installation guidelines
Removing and replacing server components
System reliability guidelines
Working inside the server with the power on
Handling static-sensitive devices
Returning a device or component
Connecting the cables
Installation Instructions that come with the server
Removing and replacing self-service CRUs
Removing the side cover
Installing the side cover
Removing the lower bezel
Installing the lower bezel
Removing the upper bezel
Installing the upper bezel
Removing an adapter
Installing an adapter
Rear adapter retention bracket
Removing and installing internal drives
Removing a CD or DVD drive
Installing a CD or DVD drive
Removing a tape drive
Installing a tape drive
Removing a hot-swap hard disk drive
Installing a hot-swap hard disk drive
Drive-tray
Removing a simple-swap hard disk drive
Installing a simple-swap hard disk drive
Removing a hot-swap power supply
Page
Installing a hot-swap power supply
Removing a memory module
Installing a memory module
Installing the battery
Removing and replacing optional-service CRUs
Removing the battery
Do not
Removing the rear system fan
Installing the rear system fan
Removing the hard disk drive fan assembly
Removing and replacing server components
Installing the hard disk drive fan assembly
Removing the simple-swap backplate
Page
Installing the simple-swap backplate
Removing the SAS/SATA hard disk drive backplane
Installing the SAS/SATA hard disk drive backplane
Page
Removing the front-panel assembly
Installing the front-panel assembly
Removing the front USB connector assembly
Removing the rear adapter retention bracket
Installing the rear adapter retention bracket
Removing the front adapter-retention bracket
Installing the front adapter-retention bracket
Installing the front USB connector assembly
Removing the hot-swap power supply cage
Installing the hot-swap power supply cage
Removing the mini-SAS/SATA controller
Installing the SAS/SATA controller
Removing the optional mini-PCI-X enablement card
Installing the optional mini-PCI-X enablement card
Removing the RAID-MR10i SAS/SATA controller
Installing the RAID-MR10i SAS/SATA controller
Hard disk drive cable connectors 4
Page
1 Remote Supervisor Adapter II SlimLine adapter
Page
Removing a non-hot-swap power supply
Removing and replacing FRUs
Page
Installing a non-hot-swap power supply
Removing the microprocessor and fan sink
Removing and replacing server components
Installing a microprocessor and fan sink
Thermal grease
Page
Removing the system board
Fan-sink mounting bracket slots
Installing the system board
Page
Removing and replacing server components
Page
Diagnostic tools
Post beep codes, error messages, and error logs
Troubleshooting tables
Diagnostic programs and messages
Post beep codes
Diagnostics
No-beep symptoms
System-event/error log
Error logs
Post error log
Page
Post error codes
Cmos
SlimLine firmware seeUpdating the firmware on
Page
Diagnostics
See the User Guide on the ThinkServer
Diagnostics
Page
Bist
Page
Checkout procedure
About the checkout procedure
Performing the checkout procedure
Troubleshooting tables
CD or DVD drive problems
Page
General problems
Hard disk drive problems
Intermittent problems
Keyboard, mouse, or pointing-device problems
Diagnostics
Memory problems
Microprocessor problems
Monitor or video problems
Page
Optional-device problems
Power problems
Serial port problems
EasyStartup problems
Software problems
Universal Serial Bus USB port problems
Error LEDs
Power supply LEDs
LED
Diagnostic programs and messages
Running the diagnostic programs
Diagnostic text messages
Diagnostic messages
Viewing the test log
Diagnostic messages
089-803-xxx
089-901-xxx
Advanced Setup RSA II Settings
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
BMC
166-802-xxx
166-803-xxx
166-804-xxx
166-805-xxx
166-806-xxx
166-807-xxx
166-808-xxx
166-809-xxx
166-810-xxx
166-811-xxx
166-812-xxx
166-813-xxx
166-814-xxx
166-815-xxx
166-816-xxx
166-817-xxx
166-818-xxx
166-819-xxx
166-820-xxx
166-821-xxx
166-822-xxx
166-823-xxx
166-824-xxx
166-901-xxx
166-902-xxx
166-903-xxx
166-904-xxx
166-905-xxx
166-906-xxx
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Run the memory diagnostics to identify
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Diagnostic messages
Updating flash-update the Bios code on the server
Recovering from a Bios update failure
Diagnostics
Page
Information
System-error log messages
Error
ENETeee IP-CfgHstName=x Information only
IP@=aaa.aaa.aaa.aaa, Remote
Client at IP@=yyy.yyy.yyy.yyy
CPU
Page
Diagnostics
Page
Solving SAS problems
Solving power problems
Solving Ethernet controller problems
Solving undetermined problems
Problem determination tips
Appendix A. Getting help and technical assistance
Before you call
Calling for service
Using other services
Purchasing additional services Lenovo Taiwan product service
Page
Appendix B. Notices
Trademarks
Important notes
Waste electrical and electronic equipment Weee notices
Battery return program
For the European Union
For California
Industry Canada Class a emission compliance statement
Avis de conformité à la réglementation dIndustrie Canada
European Union EMC Directive conformance statement
German Class a compliance statement
Appendix B. Notices
Page
Index
Ethernet
Ipmi
POST/BIOS
Removing
Page
Page
Part Number 46U0853