Lenoxx Electronics Optima 3 FS Thermostat Installation, Terminal Block for Thermostat

Models: Optima 3 FS

1 54
Download 54 pages 40.05 Kb
Page 13
Image 13
THERMOSTAT INSTALLATION:

INSTALLATION

THERMOSTAT INSTALLATION:

NOTE: Always Disconnect Power Before Performing The Thermostat Installation.

A 24 volt wall thermostat and 20 feet of 18-gage thermostat wire is included in your stoves accessory package. It is rec- ommended that the thermostat and thermostat wire be installed by an authorized Lennox Hearth Products dealer. Installation Steps:

1.Unplug stove power cord from the wall outlet.

2.Locate the thermostat terminal block (see illustrations below).

3.Loosen the two terminal screws on the terminal block and remove the jumper.

4.Connect the two wires from your thermostat to the terminals (one per terminal). Ensure that the purple wires from the harness remain connected to the terminal block and tighten the terminal screws. Make sure the wires are firmly con- nected to the thermostat.

5.Plug in the stove and you are ready to operate with your thermostat!

IMPORTANT: IF THE WALL THERMOSTAT PROVIDED IS NOT USED, THE JUMPER IS REQUIRED FOR THE STOVE TO OPERATE.

Terminal Block for Thermostat

Leave Jumper on, If Thermostat Is Not Used

Remove Jumper if Thermostat Is To Be Used

Jumper

Model: Optima 3 FS

Terminal Block for Thermostat Terminal Block for Thermostat

Model: Optima 3 INS

(on right side of insert when viewed from the front)

Th

Terminal Block for Thermostat

Power Cord

Connector

Model: Optima 2 FS

(viewed from stove back)

Terminal Block

Power Cord

for Thermostat

Connector

Power Cord Connector

PAGE 13

Page 13
Image 13
Lenoxx Electronics Thermostat Installation, Terminal Block for Thermostat, Model Optima 3 FS, Model Optima 3 INS