![THERMOSTAT INSTALLATION:](/images/new-backgrounds/35437/3543725x1.webp)
INSTALLATION
THERMOSTAT INSTALLATION:
NOTE: Always Disconnect Power Before Performing The Thermostat Installation.
A 24 volt wall thermostat and 20 feet of
1.Unplug stove power cord from the wall outlet.
2.Locate the thermostat terminal block (see illustrations below).
3.Loosen the two terminal screws on the terminal block and remove the jumper.
4.Connect the two wires from your thermostat to the terminals (one per terminal). Ensure that the purple wires from the harness remain connected to the terminal block and tighten the terminal screws. Make sure the wires are firmly con- nected to the thermostat.
5.Plug in the stove and you are ready to operate with your thermostat!
IMPORTANT: IF THE WALL THERMOSTAT PROVIDED IS NOT USED, THE JUMPER IS REQUIRED FOR THE STOVE TO OPERATE.
Terminal Block for Thermostat
Leave Jumper on, If Thermostat Is Not Used
Remove Jumper if Thermostat Is To Be Used
Jumper
Model: Optima 3 FS
Terminal Block for Thermostat
Model: Optima 3 INS
(on right side of insert when viewed from the front)
Th
Terminal Block for Thermostat
Power Cord
Connector
Model: Optima 2 FS
(viewed from stove back)
Terminal Block | Power Cord |
for Thermostat | Connector |
Power Cord Connector
PAGE 13