SPECIFICATIONS - Optima 2 FS
Flue Size
Width, Overall
Depth, Overall
Depth, Overall w / 3” tee
Height
Floor to Rear
Flue Center
Facing back of unit, outside edge of left side to center of rear
flue outlet center
Floor to Rear Outside Air Inlet Located on center- line of pedestal back
Facing back of Unit outside edge of right side to center of air inlet
Floor Protection
Requirements
Standard Features
Hopper Capacity
Burn time
Fuse, Control Board
Fuse, Igniter
Heat Input (BTU’s per hour) Overall Efficiency
Emissions
Shipping Weight
Room Air Blower
Auger Motor
Exhaust Blower
Fastfire Igniter
Options
3” / 76mm Rear
23” / 584mm
22 3/4” / 578mm
28 1/2” / 724mm
28 5/8” / 727mm
11 1/4” / 286mm
6 1/2” / 165mm
5” / 127mm
11 1/2” / 292mm
+Front and Sides:6”/152mm
Back: Up to 6” / 152mm
Fastfire Self Igniter
Wall Thermostat (wire in- cluded)
55 lbs.
♦
5 Amp, 250 volt, 3AG *
6 Amp, 125 volt *
♦
♦0.4 gr / hr (varies w/size and type of fuel) EPA ex- empt.
215 lbs.
150 CFM; .8 Amps,
2175 rpm
1 RPM; .4 Amps
95 CFM: 1.0 Amps,
2880 rpm
4.35 Amps,
Nickel or Gold Trim Kits 4” Quick Disconnect Log Set
BACK VIEW
23"
28 5/8"
|
| 6 ½" |
|
|
| |
11 ¼" |
|
| ||||
|
|
|
|
| 8 ¾" | |
|
|
|
|
|
| |
|
|
| 11 1/2" | 5 1/8" | ||
|
|
| ||||
|
|
|
| |||
|
|
|
|
|
|
SIDE VIEW
28 1/2"
22 3/4"
Note: Dimensions shown are approximations only (+/- ¼”)
+
♦Fuel delivery and burn times will vary depending on size and type of fuel used. Estimated heat in- put based on fuel value of 8400 BTU per lb.
*Fuses are rated as fast blow.
PAGE 34