FLOOR PROTECTION - Optima 2 FS

PLANNING YOUR INSTALLATION

FLOOR PROTECTION - Optima 2 FS

This appliance requires noncombustible floor protec- tion. If the floor protection is to be stone, tile, brick, etc., it must be mortared or grouted to form a continuous non-combustible surface. If a chimney connector ex- tends horizontally over the floor, the protection must cover the floor under the connector and at least 2" to either side.

A noncombustible floor protector must fully cover the area beneath the appliance and extend 6” to the front, 6” to the sides, and up to 6" from the back as illus- trated on this page.

*Note: When installed at clearances less than 6”, floor pro- tection is only required to extend to the wall.

Top View of Model: Optima 2 FS

Up to * 6"/153mm minimum

Rear

6"/

6"/

153mm

153mm

min.

min.

Front

6"/

153mm

min..