INSTALLATION
Standard Horizontal Installation Configurations
Optima 3 FS
Corner Through the Wall
3” (75 mm) Mini- mum clearance be- tween wall and pipe. If you vent to the furthest wall, the vent pipe must maintain a 3” clear- ance parallel to the other wall.
Wall
Top View Illustration
Wall
Optima 2 FS
Corner Through the Wall
3” (75 mm) Minimum clearance between wall and pipe. If you vent to the furthest wall, the vent pipe must maintain a 3” clearance parallel to the other wall.
Wall | 2" |
|
Top View Illustration
Wall
2"
Optima 2 FS and Optima 3 FS
Horizontal Vent Through the Wall
2" / 51 mm
Minimum
12" / 305 mm Minimum From Outer Wall
6" / 152 mm
Minimum
45 Degree
Elbow
Hearth Pad / | 12" / 305 mm From |
Floor Protection | Ground or Other Surface |
Note: Horizontal run of pipe requires 1/4” (7 mm) rise per foot.
PAGE 18