Standard Horizontal Installation Configurations

INSTALLATION

Standard Horizontal Installation Configurations

Optima 3 FS

Corner Through the Wall

3” (75 mm) Mini- mum clearance be- tween wall and pipe. If you vent to the furthest wall, the vent pipe must maintain a 3” clear- ance parallel to the other wall.

Wall

Top View Illustration

Wall

Optima 2 FS

Corner Through the Wall

3” (75 mm) Minimum clearance between wall and pipe. If you vent to the furthest wall, the vent pipe must maintain a 3” clearance parallel to the other wall.

Wall

2"

 

Top View Illustration

Wall

2"

Optima2 FS and Optima3 FS

Horizontal Vent Through the Wall

2" / 51 mm

Minimum

12" / 305 mm Minimum From Outer Wall

6" / 152 mm

Minimum

45 Degree

Elbow

Hearth Pad /

12" / 305 mm From

Floor Protection

Ground or Other Surface

Note: Horizontal run of pipe requires 1/4” (7 mm) rise per foot.