BEKOMAT 21

 

 

Function • Funcionamiento

 

 

english

 

Fonctionnement • Funcionamento

 

 

 

 

1

 

 

 

 

 

 

The condensate flows through the feed

 

 

 

 

 

 

 

line (1) into the BEKOMAT unit and

 

 

 

 

 

 

 

accumulates in the container (2). A

 

 

 

 

 

 

 

capacitive sensor (3) continuously re-

 

 

 

 

 

 

 

gisters the liquid level and passes a

 

 

 

 

 

 

 

signal to the electronic control as

 

 

 

 

 

 

 

soon as the container is filled. The

 

 

 

 

 

 

4

pilot valve (4) is then activated and the

 

 

 

 

 

 

 

diaphragm (5) opens the outlet line

 

 

 

 

 

 

 

(6) for discharging the condensate.

 

 

 

 

 

 

 

When the BEKOMAT unit has been

 

 

 

 

 

 

 

emptied, the outlet line is closed

2

3

 

 

 

5

6

again quickly and tightly without wa-

 

 

 

sting compressed air.

 

 

 

 

 

 

 

 

 

 

BEKOMAT 21

 

 

The operating states of the BEKOMAT

 

 

 

 

 

 

 

21 are indicated by one LED with dif-

Power

 

1

Power

 

ferent flashing frequencies.

 

 

TEST

2

 

 

TEST

1

Ready for operation

 

 

 

 

Power on

Valve

Alarm

 

3

Valve

Alarm

 

2

Discharge procedure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet line open

 

 

BEKOMAT 21 PRO

 

If the condensate discharge is not func-

 

 

 

tioning properly, the valve will keep

 

 

 

 

 

 

 

opening (about every 3 seconds) so as

Alarm

 

 

Alarm

 

 

to clear the fault automatically, if

Valve

TEST

 

Valve

 

TEST

possible.

 

 

 

Malfunction /Alarm

Power

 

1

Power

 

2

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Test of valve function and

Alarm

 

 

 

 

 

manual drainage: briefly press

 

 

Alarm

 

 

 

button.

Valve

TEST

 

Valve

 

TEST

Additional feature of the BEKOMAT 21

 

 

 

3

 

4

Power

 

Power

 

PRO: press button for > 1 minute to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

test the alarm function (s. below).

Switching sequence of valve in alarm mode

 

 

The BEKOMAT 21 PRO also has an

Secuencia de apertura de la válvula en el modo de alarma.

alarm-mode function:

Séquence d'activation de la vanne en modeAlarme

7,5 sec

If normal conditions have not been re-

stored after 1 minute, a fault signal

Sequência de ligação da válvula no modo de alarme

> <

will be triggered:

 

 

 

 

 

 

 

 

 

 

 

 

 

• Alarm LED flashes.

 

 

 

 

 

 

 

• Alarm signal switches over (can be

 

 

 

 

 

 

 

transmitted via potential-free con-

 

 

 

 

 

 

 

tact).

 

 

 

 

 

 

 

• Valve opens every 4 minutes for a

 

 

 

 

 

 

 

period of 7.5 seconds.

 

 

 

 

 

 

 

Once the fault is cleared, the

< 1 min ><

3 min

>< 4 min

><

4 min

>

BEKOMAT 21 PRO will automatically

switch back to the normal mode of

 

 

 

 

 

 

 

operation.

 

 

 

 

 

 

 

Malfunctioning could be caused

 

 

 

 

 

 

 

by, e.g.:

 

 

 

 

 

 

 

• Mistakes during installation

 

 

 

 

 

 

 

• Dropping below the necessary mi-

Alarm signal via potential-free contact (only BEKOMAT 21 PRO)

nimum pressure

Mensaje de alarma a través de contacto sin potencial (solamente BEKOMAT 21

• Excessive condensate quantities

PRO)

 

 

 

 

 

 

(over-loading)

 

 

 

 

 

 

• Blocked/shut off outlet line

Signal d'alarme délivré sur le contact sans potentiel(uniqu. BEKOMAT 21 PRO)

• Extreme amount of dirt particles

Sinal de alarme via contacto isento de potência (só BEKOMAT 21 PRO)

• Frozen piping

 

 

 

 

 

 

 

4