TRIGGER OUTPUTS

MAIN AUDIO OU

3
1234
MICROPHONE INPUTS
LFE
SETUP
MC-12
3-35

Step A: Connecting the Microphones

The microphones included in the Lexicon Microphone Kit
require careful handling. Dropping or otherwise physically
abusing the microphones might cause errors during use or
irreparable damage to the microphone.
Never make or break microphone input connections unless
the MC-12 is powered off with the rear panel power switch
OR standby mode is activated with the front panel or remote
control standby button.
CAUTION
MC-12 Rear Panel
Note the following:
Automatic calibration requires the microphones included in the
Lexicon Microphone Kit available at authorized Lexicon dealers.
Performing automatic calibration with other microphones will
produce unknown results.
Proper microphone placement is essential to achieving the
desired automatic calibration results. Pay particular attention to
the microphone placement instructions and illustrations
included in this section.
It is important to read and observe the care and handling
documentation included with the Lexicon Microphone Kit to
ensure optimal microphone performance.
A-1. Make sure the MC-12 is powered off with the rear panel
power switch OR standby mode is activated with the front
panel or remote control standby button.
A-2. Connect the microphones included in the Lexicon
Microphone Kit to the microphone input connectors on the
MC-12 rear panel shown above. Make sure the microphone
cable plug is fully inserted for a solid connection.
During the microphone check, the microphones will be
referred to as 1, 2, 3, and 4 based on the input connector to
which the microphone is connected. It is recommended to
label the microphones for troubleshooting purposes.
A-3. Power on the MC-12 with the rear panel power switch OR
deactivate standby mode with the front panel or remote
control standby button.