012 - IR BANKS EN (IR Banks Enable)

Installer Menu (Cont.)

012 - IR BANKS EN (IR Banks Enable)

For direct access to a particular channel bank. When enabled, you can access a channel bank by inputting the IR code for the bank.

013 - SCAN MODE (Functional after 2-5-5 + MENU setup transfer)

Allows variation in turning the TV On/Off with Channel Up/Down. You may opt for TV channels only or TV channels + Off/On. If set to 0, Channel Up/Down keys change channels only. If set to 1, channel DOWN below the lowest channel or Channel UP above the highest channel to turn the TV Off.

014 - STRT CH IN SM (Start Channel in Scan Mode)

If set to 1, installs TV On/Off event below the start channel at TV turn On. If set to 1, the user can select channels with either Channel Up/Down or by direct keypad entry. If set to 0, only those channels that are entered for scanning can be selected.

015 - SLEEP TIMER

If set to 1, the Sleep Timer feature may be used. If set to 0, the Sleep Timer is not available.

016 - EN TIMER (Enable On/Off Timers) *

If set to 1, the Timer function is available to the end user and enabled continuously. Set to 0 to disable On/Off Timers.

Note: Clock must be set in order to use timers.

017 - ALARM *

Gives the installer the option of making the Alarm function avail- able to the end user. If set to 1, the Alarm function is available to the end user. Set to 0 to disable the Alarm function.

Note: Clock must be set before the Alarm function will work.

020 - FEATURE LEVEL

Leave item 20 FEATURE LEVEL set to 1 (default). Default set to ZEN 1 for Zenith IR codes remote control operation. Set O, P LBL for Zenith Private Label IR remote control operation.

Warning: Do not set to “0” or remote will not control TV.

021 - V-CHIP (Parental Control) *

Set to 1 to activate V-Chip (Parental Control) and have it available to the end user to filter and control or otherwise restrict program- ming content that can appear. Set to 0 to turn the V-Chip feature Off (not available to user); no programming restrictions can be set.

022 - MAX BLK HRS (Maximum Block Hours) *

Sets hours from 0 to 99 for the maximum V-Chip (Parental Con- trol) block hours. Default setting is for 12 blocking hours.

023 - CAPTION LOCK

If set to 0, captions are OFF when the TV is turned ON. Set to 1 to use the caption setting configured before the TV was turned Off when the TV is turned ON.

* Only affects Function Menu if enabled by some PPV providers.

025 - FUNCTION PRE (Function Preview)

Set to 0 to suppress CHANNEL PREVIEW from the Function Menu with some Pay-Per-View systems.

027 - HOSPITAL MODE

With this setting two things are affected: Channel Banks 1, 2, and 3 are accessible, while Channel Bank 4 can be made inactive by removing all the channels from Channel Bank 4. Then, if Channel Bank 4 is selected when the TV is turned On, the TV screen will show “Inactive TV.” The Channel Bank 4 setup allows the hospital to present TV viewing options to the patient. The patient can select programming options available in Channel Banks 1, 2, or 3. Chan- nel Banks are available in all Hospital Modes (1, 2, etc.).

The IR code that will control the TV depends on the Installer Menu item 020 FEATURE LEVEL setting.

For LG3DCH TVs

It is recommended that you leave this item set to 2 (default), which favors most hospitals.

Hosp. Mode = 0 Hospital Mode disabled.

Hosp. Mode = 1 Zenith Private Label IR Code (Bed 1) Hosp. Mode = 2 Zenith Consumer IR Code (Bed 2)

For LG3DDH TVs

Set according to the pillow speaker supply voltage and audio source (see table below). Note the following regarding pillow speak- er voltage: +12 v identifies a Zenith pillow speaker, +5 v identifies a Phillips pillow speaker, and -5 v identifies an RCA pillow speaker.

Note: The default setting (254) is not selectable in the Installer Menu. If you ever need to restore the default setting, you must set item 117 FACT DEFAULT to 1 to reload the factory default settings. See item 117 description for further information.

Item 27

Hospital Mode

Pillow

Audio Source

Speaker

(Switch = Pil-

Value

 

Voltage

low)

 

 

000

Disabled

+12 v

Pillow Only

001

Enabled, Zenith Private Label

+12 v

Pillow Only

002

Enabled, Zenith Consumer

+12 v

Pillow Only

017

Enabled, Zenith Private Label

+5 v

Pillow Only

018

Enabled, Zenith Consumer

+5 v

Pillow Only

033

Enabled, Zenith Private Label

-5 v

Pillow Only

034

Enabled, Zenith Consumer

-5 v

Pillow Only

065

Enabled, Zenith Private Label

+12 v

Main Only

066

Enabled, Zenith Consumer

+12 v

Main Only

081

Enabled, Zenith Private Label

+5 v

Main Only

082

Enabled, Zenith Consumer

+5 v

Main Only

097

Enabled, Zenith Private Label

-5 v

Main Only

098

Enabled, Zenith Consumer

-5 v

Main Only

129

Enabled, Zenith Private Label

+12 v

Pillow & Main

130

Enabled, Zenith Consumer

+12 v

Pillow & Main

145

Enabled, Zenith Private Label

+5 v

Pillow & Main

146

Enabled, Zenith Consumer

+5 v

Pillow & Main

161

Enabled, Zenith Private Label

-5 v

Pillow & Main

162

Enabled, Zenith Consumer

-5 v

Pillow & Main

254

Enabled, Zenith Consumer

0 v

Main Only

206-4096

21

Page 21
Image 21
LG Electronics 22LG3DCH, 32LG3DDH, 32LG3DCH, 22LG3DDH, 26LG3DCH, 26LG3DDH Installer Menu Cont, IR BANKS EN IR Banks Enable