Part 2 Functions & Controls

4. UtilityFunctions

4.1 Forced operation

To operate the appliance manually in case when the remote control is lost, the forced operation selection switch is on the main unit of the appliance, and operate the appliance in the standard conditions.

The operating condition is set according to the outdoor temp. and intake air temperature as follows.

Indoor temp.

Operating Mode

Setting temp.

Setting speed of

indoor fan

 

 

 

 

 

 

 

over 24°C(75.2°F)

Cooling

22°C(71.6°F)

 

 

 

 

High speed

21~24°C(69.8~75.2°F)

Healthy Dehumidification

23°C(73.4°F)

 

 

 

 

below 21°C(69.8°F)

Heating

24°C(75.2°F)

 

 

 

 

 

The unit select the last operation mode in 3 hours.

Operating procedures when the remote control can't be used is as follows :

-The operation will be started if the ON/OFF button is pressed.

-If you want to stop operation, re-press the button.

-The ON/OFF switch is on the display PCB or side of indoor unit

4.2 Auto cleaning operation

Function used to perform Self Cleaning to prevent the Unit from Fungus and bad odor.

Used after the Cooling Operation before turning the unit off, clean the Evaporator and keep it dry for the next opera- tion.

The function is easy to operate as it is accessed through the Remote controller.

Unit

ON

 

 

 

 

 

 

 

Operation

OFF

 

 

 

 

 

 

 

Indoor

ON

 

 

 

 

 

 

 

Fan

OFF

 

 

 

 

Setting step

L Low

 

OFF

 

ON

 

 

 

Comp.

OFF

 

 

 

 

 

 

 

Time

 

13~14 minutes

1 minute

2~3 minutes

 

 