Part 2 Functions & Controls
4. UtilityFunctions
4.1 Forced operation
•To operate the appliance manually in case when the remote control is lost, the forced operation selection switch is on the main unit of the appliance, and operate the appliance in the standard conditions.
•The operating condition is set according to the outdoor temp. and intake air temperature as follows.
Indoor temp. | Operating Mode | Setting temp. | Setting speed of | |
indoor fan | ||||
|
|
| ||
|
|
|
| |
over 24°C(75.2°F) | Cooling | 22°C(71.6°F) |
| |
|
|
| High speed | |
21~24°C(69.8~75.2°F) | Healthy Dehumidification | 23°C(73.4°F) | ||
|
|
|
| |
below 21°C(69.8°F) | Heating | 24°C(75.2°F) |
| |
|
|
|
|
•The unit select the last operation mode in 3 hours.
•Operating procedures when the remote control can't be used is as follows :
-The operation will be started if the ON/OFF button is pressed.
-If you want to stop operation,
-The ON/OFF switch is on the display PCB or side of indoor unit
4.2 Auto cleaning operation
•Function used to perform Self Cleaning to prevent the Unit from Fungus and bad odor.
•Used after the Cooling Operation before turning the unit off, clean the Evaporator and keep it dry for the next opera- tion.
•The function is easy to operate as it is accessed through the Remote controller.
Unit | ON |
|
|
|
|
|
|
| |
Operation | OFF |
|
|
|
|
|
|
| |
Indoor | ON |
|
|
|
|
|
|
| |
Fan | OFF |
|
|
|
| Setting step | L Low |
| OFF |
| ON |
|
|
|
Comp. | OFF |
|
|
|
|
|
|
| |
Time |
| 13~14 minutes | 1 minute | 2~3 minutes |
|
|
Service Manual 13