LG Electronics General Wall Mounted-Inverter Type manual

Models: General Wall Mounted-Inverter Type

1 67
Download 67 pages 5.96 Kb
Page 50
Image 50

Part 4 Trouble Shooting

Error code

Description

Cause of error

 

 

 

 

Heat-sink Temp. is over

Heat-sink TH. is damaged(short or open).

 

 

 

 

 

95°C(203°F)

°

°

F)

4

 

Heat-sink Temp. is over 95 C(203

 

Heat-sink TH.

 

 

 

 

• Damage or defect on the sensing circuit of outdoor pcb assembly.

 

is open or short

 

 

(R01H, R02H, C01H)

 

 

 

 

 

 

 

Check flow

Heat-sink TH is connected to outdoor PCB assembly?

No

YES

Heat-sink TH. in INV-IC is Right ?

No

YES

Sensing circuit of outdoor pcb is right ?

No

-Connect to CN-TH2 in outdoor PCB assembly

Check heat-sink TH.

-Measure resistance of TH. (about 10kat 25°C(77°F))

-Check soldering state of R01H, R02H, C01H

50Room Air Conditioner