Extron electronic ISM 824 manual Powering Up, Default display cycle

Models: ISM 824

1 166
Download 166 pages 4.54 Kb
Page 37
Image 37

 

 

 

6 feet

 

 

1

 

6

 

 

 

 

 

 

 

 

5

 

9

 

 

 

 

 

 

 

Tip

 

 

 

 

 

 

 

 

 

 

Ring

 

9-pin D

Connection

TRS Plug

Sleeve (Gnd)

 

Pin 2

 

Computer's RX line

Tip

 

 

Pin 3

 

Computer's TX line

Ring

 

 

Pin 5

Computer's signal ground

Sleeve

 

Figure 3-2 — Front 2.5 mm port configuration cable, part #70-335-01

Powering Up

When applying power to the ISM 824, the unit undergoes a start-up self testing sequence as follows:

The LCD screen lights, and displays “Extron Electronics” for 1 second.

The LCD displays “ISM 824 Version 1.00”.

All buttons light red, then green, then amber, and then extinguish, leaving the Video button lit green, the Audio button lit red, and the Menu and Next buttons both lit amber.

NIf a Universal Scaler card (ISM RGB) is installed, during power up a color bar test briefly appears on the display device.

The LCD begins the default display cycle.

NThe complete sequence above is also made when the unit is restarted after firmware uploads. If the unit is reset via the front panel, the sequence starts at the default display cycle.

Default display cycle

When in use and not in any menu mode, the LCD screen defaults to cycling through the output configuration currently installed. The displayed content may vary from installation to installation, depending on the installed output card configuration. See figure 3-3 for a typical default display cycle.

Power

on

3

sec.

 

1

 

Extron

sec.

ISM 824

Electronics

 

Version n.nn

All buttons

Video and Audio

Menu and Next

 

flash in

 

buttons remain lit.

buttons remain lit.

sequence.

 

 

 

 

1

3

 

I / O

 

 

sec.

sec.

 

 

MENU

NEXT

 

 

VIDEO

AUDIO

NThe output cards shown in the default display cycle may differ,depending on the type of cards installed.

2

sec.

1

sec.

Default Display Cycle

Card #1

Out 3/4

2

Card #2

Out 5/6

sec.

DualWideband

 

UnivScaler

 

 

 

 

 

2

 

 

2

 

sec.

Card #4

Out 8

sec.

Card #3

Out 7

Video Scaler

 

Wideband

 

Figure 3-3 — Typical default display cycle

ISM 824 Integration Scaling Multiswitcher • Operation and Setup

3-5

Page 37
Image 37
Extron electronic ISM 824 manual Powering Up, Default display cycle, LCD begins the default display cycle