Operation and Setup, cont’d

Step 1.

Step 2.

Press the Esc button to

Press the Bright/Cont button.

clear all selections.

The button lights green.

C O N T R O L

ENTER

PRESET

VIEW

ESC

COLOR/

BRIGHT/

DETAIL

POSITION

SIZE

ZOOM

TINT

CONT

PICTURE ADJUSTMENTS

The Esc button flashes

 

 

green once.

BRT OUT #5

CONT

 

128

128

 

 

 

INPUTS

 

 

 

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

 

 

 

OUTPUTS

 

 

 

The scaler output card button (#5) and associated input (#2) light green. Non tied scaler outputs (#8) flash green.

NThe LCD shows the current Bright/Cont setting.

Figure 3-34 — Steps 1 and 2 for adjusting brightness and contrast

3. Using the left front panel encoder ([), adjust the brightness (0 to 255, default is 128), and with the right ({) encoder, adjust the contrast (0 to 255, default is 128).

NBrightness and contrast adjustments are not available for scan converter cards. 4. Press the Esc button to clear all button and reset the LCD.

Adjusting the picture detail

To adjust the picture detail do the following:

1.

Press the Esc button to clear all pending changes and reset the LCD.

2.

Press and release the detail adjustment button. The output buttons for scaler

 

/scan converter cards (outputs 3 through 8) and any associated (tied) input

 

buttons light solid green. Untied outputs flash green. The LCD panel shows

 

the current detail setting (see figure 3-35) for that lit output.

NAll applicable outputs light or flash green. To change to a different output, press the desired output button. The selected button will light green

Step 1.

Press the Esc button to clear all selections.

 

C O N T R O L

 

ENTER

PRESET

VIEW

ESC

Step 2.

Press the Detail button. The button lights green.

COLOR/

BRIGHT/

DETAIL

POSITION

SIZE

ZOOM

TINT

CONT

 

 

 

 

PICTURE ADJUSTMENTS

INPUTS

1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

OUTPUTS

The Esc button flashes

 

green once.

OUT #5 DETAIL

 

128

NThe LCD shows the current detail setting.

The scaler output card button (#5) and associated input (#2) light green. Non tied inputs (#8) flash green.

Figure 3-35 — Steps 1 and 2 for adjusting detail

3. Using either of the front panel encoders ([ or {), adjust the detail.

NFor Universal Scaler cards, detail range is 0 to 255, default is 128, and for Video Scaler cards, detail range is 0 to 63, default is 16.

4. Press the Esc button to clear all button and reset the LCD.

3-24 ISM 824 Integration Scaling Multiswitcher • Operation and Setup

Page 56
Image 56
Extron electronic ISM 824 manual BRT OUT #5, Adjusting the picture detail