ISM 824 Integration Scaling

Command/response table for SIS commands (continued)

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to switcher)

(host to switcher)

(switcher to host)

 

 

 

 

 

 

Query firmware version

Q/q

Q/q

Ver01*x.xx]

View the firmware version.

View internal temperature

7S

7S

Sts7X1@]

Internal temperature in

 

 

 

 

degrees Fahrenheit.

Digital sync validation

X! LS

X! LS

X4*,X4*]

Listed as horizontal and

processing (DVSP)

 

 

 

vertical frequencies.

View input video standard

38 *X!#

21 %2A X! #

Ist X!* X1!]

View setting.

 

 

 

 

 

With verbose 2/3 not activated

 

 

 

 

GGeneral information

I/i

I/i

X\•X\•X\•X\

Query the configuration of all

 

 

 

•X\•X\•X\•X\]

outputs (listed 1-8).

Query part number

N/n

N/n

60-787-01]

View the part number (based

 

 

 

 

unit).

Query part number for slots

*N/n

*N/n

60-787-01.X\

View the part number (slot

 

 

 

X\ X\ X\]

population from slot 1-4).

Where::X\ = Output (card) type

Multiswitcher • SIS

Query firmware version

View internal temperature

View input video standard

OOthers:

A = Universal scaler

D =Dual-output wideband

B = Video-only scaler

E = Scan converter

C = Single-output wideband

 

X = No output present

Z = Internal wideband output (outputs 1 and 2)

Q/q

Q/q

7S

7S

38 *X!#

38 %2A X! #

x.xxx]

View the firmware version.

Sts 7 X1(]

Internal temperature in degrees

 

Fahrenheit.

X1!]

View setting.

Programming and Control 4-13

Front panel lockout (executive mode)

Enable lockout

1X

1X

Exe1]

Lock front panel (admin).

Enable Admin lockout

2X

2X

Exe2]

Lock front panel (complete).

Disable lockout

0X

0X

Exe0]

Unlock front panel.

View lockout status

X

X

x!]

Show executive mode status

 

 

 

 

x! = 0 (off), 1 (view only),

or 2 (I/O ties only).