Operation and Setup, cont’d

Editing the communication settings

To edit the communication settings, do the following:

NThe hardware address (the MAC address) is hard coded and cannot be changed. In edit mode the MAC addresss menu is not displayed.

1.

Press the Enter, Preset, View, and Esc buttons at the same time, and hold

 

down for 2 seconds. The LCD displays the Edit Comm Settings menu.

2.

Press the Next button to enter the first sub level, Remote Port.

3.

Rotate the left front panel encoder ([) to adjust the baud rate (9600, 19200,

 

38400, or 115200), and rotate the right encoder ({) to select the connection

 

type (RS-232/RS-422).

4.

Press Next to go to the front panel’s Config Port menu.

5.

Rotate the left front panel encoder ([) to adjust the baud rate (9600, 19200,

 

38400, or 115200), and rotate the right encoder ({) to select the connection

type (RS-232).

NThe hardware address (the MAC address) is hard coded and cannot be changed. In edit mode the MAC addresss menu is not displayed.

6.

Press Next to go to the DHCP Mode menu. From this menu, DHCP (Dynamic

 

Host Configuration Protocol) can be turned on or off. Default setting is off.

7.

Rotate either front panel encoder to turn the DHCP mode on or off.

8.

Press Next to go to the IP Address menu. In this menu the IP address of the

 

ISM 824 multiswitcher can be changed as desired. Valid IP addresses consist

 

of four 1-, 2-, or 3-digit numeric subfields separated by dots (periods). Each

 

field can be numbered from 000 through 255. Leading zeroes, up to 3 digits

 

total per field, are optional. Values of 256 and above are invalid. The default

 

IP address is 198.162.254.254.

9.

Rotate the left front panel encoder ([) to select the field to be changed (the

 

field value flashes when selected), then rotate the right encoder ({) to change

 

the field values.

10. Press Next to go to the Subnet Mask menu. In this menu the Subnet mask

 

of the ISM 824 multiswitcher can be changed as desired. The default is

 

255.255.000.000

11.

Rotate the left front panel encoder ([) to select the field to be changed, then

 

rotate the right encoder ({) to change the field values.

12.

Press Next to go to the Gateway Address menu. In this menu the Gateway

 

address of the ISM 824 multiswitcher can be changed as desired. The default

 

is 000.000.000.000

13. Rotate the left front panel encoder ([) to select the field to be changed, then rotate the right encoder ({) to change the field values.

14. Press Next to return to the upper level Edit Comm Settings menu.

NPress the Menu button to go directly to the next top level (System Reset) menu.

3-42 ISM 824 Integration Scaling Multiswitcher • Operation and Setup

Page 74
Image 74
Extron electronic ISM 824 manual Editing the communication settings