Extron electronic manual ISM 824 I/O Group Settings menus − all groups cleared

Models: ISM 824

1 166
Download 166 pages 4.54 Kb
Page 110
Image 110

ISM 824 Multiswitcher Software, cont’d

Executive mode — The Executive mode locks out some or all of the front panel features, and has three levels. Select the mode level applicable.

View mode – This locks out the front panel menu, picture adjustment, input, and output buttons but allows a user to view the ties.

I/O ties only – This locks out the front panel menu and picture adjustment buttons but allows a user to make, remove, and view the ties, recall I/O presets, adjust gain/attenuation, and control backlight (on/off).

Off – This turn off the executive mode. Full front panel configuration is possible.

NWhen any executive mode is enabled, only front panel operations are affected. Full configuration is still available via control software or Ethernet.

When the unit’s executive mode is set to View mode, the Video, and Audio buttons flash when a locked out front panel operation is attempted.

When the unit’s executive mode is set to I/O ties only, the Enter, Video, and Audio buttons flash when a locked out front panel operation is attempted.

I/O Group Settings — This menu allows the user to make, change, and view input to output (I/O) groupings.

To set or change I/O groupings, do the following:

1. Click on the menu to open a new window. This window (see figure 5-10) shows the free (ungrouped) input and output buttons, and eight grouping boxes (input groups 1-4, and output groups 1-4).

Figure 5-10 — ISM 824 I/O Group Settings menus − all groups cleared

2.Drag any input or output button into any of the applicable group boxes.

NOnly inputs can be placed into the input groups, likewise only outputs can be placed into the output groups.

Grouped inputs only output to the same numbered output group (e.g. in figure 5-11, input 5 within group 1, only outputs to outputs 1 and/or 4).

5-8 ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software