HTML Operation, cont’d

Also from this page adjustments to the following can be made;

picture controls (color, tint, contrast, brightness, detail, horizontal and vertical position and size, and zoom)

input samplings (horizontal and vertical start, pixel phase, total and active number of pixels and lines, and input aspect ratio)

user and input presets can be saved and/or recalled

output configuration parameters (resolution, refresh rate, sync format, and polarity) can be changed

advanced configuration settings (test patterns, film mode, blue mode, RGB pass through, auto memory, and auto image) can be turned on or off.

To make picture control adjustments do the following:

1. Within the Picture Controls section, select the setting that is to be changed, and click on either the left arrow (<) to decrease the value, or on the right arrow (>) to increase the value, one step at a time. After every click the page refreshes and shows the new value. The device is updated to the new setting.

NAlternatively, if the new setting value is known, enter it directly into the field, and press enter. The page refreshes, shows the new value, and the device is updated.

To adjust the input sampling, do the following:

1. Within the Input Sampling section, select the setting that is to be changed, and click on either the left arrow (<) to decrease the value, or on the right arrow (>) to increase the value, one step at a time. After every click the page refreshes and shows the new value. The device is updated to the new setting.

NAlternatively, if the new setting value is known, enter it directly into the field, and press enter. The page refreshes, shows the new value, and the device is updated.

For an aspect ratio other than the one currently displayed (16:9 or 4:3), click on the blank radio button. The button fills and the device is updated to the new setting).

To save and recall presets do the following:

1. Select either the User presets or Input presets drop down arrows as desired (see figure 6-18).

NThere are 3 user presets and 128 input presets. Each preset can be individually configured for the range of adjustments available for that output card.

2.

Click Save to save current configuration to that preset number, or click Recall

 

to recall that preset as the current configuration.

To change any output configuration parameter, do the following:

1. Within the Output Configuration section, select the setting to be changed, and click on the drop down arrow. A drop down list appears. Scroll down the list the desired value and click. The page refreshes and the new value is shown.

The device is updated to the new setting.

To change the advanced configuration settings do the following:

NThe advanced settings for the Universal Scaler card are test pattern selection, film mode, blue mode, auto memory, auto image, and RGB pass through.

1. For test patterns, click the drop down arrow to see a list. Scroll down to the required test pattern listed, and click. The display shows the selected pattern.

2.Within the Advanced Setting section, click the check boxes of the settings to be turned on or off as desired. The device is updated to the new setting.