4-12 ISM 824

Command/response table for SIS commands (continued)

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to switcher)

(host to switcher)

(switcher to host)

 

 

 

 

 

 

Names

 

 

 

 

NName 12 characters maximum for global preset, input, and output names. Uper- and lower-case alphanumeric characters and _ : = / and spaces are valid.

The following characters are invalid in the name: {space} ~ , @ = ‘ [ ]{ } < > ´ “: ; \ and ?.

SIS

Integration Scaling

Name global (I/O) preset

Esc X4(,name NG}

WX4(, name NG

Read global (I/O) preset

Esc X4( NG}

WX4( NG

Write input

Esc X!,name NI}

WX!, name NI

Read input

Esc X! NI}

WX! NI

Write output

Esc X@,name NO}

WX4(, name NO

Read output

Esc X@ NO}

WX4( NO

Nmg X4(, name]

Name the preset.

name]

Show reset name.

Nmi X!, name]

Write the input name.

name]

Read the input name.

Nmo X@, name]

Write the output name.

name]

Read the output name.

Programming

Start auto image

Start auto image

14*X@ #

14%2AX@ #

ImgX@]

Auto image input tied to

 

 

 

 

output X@.

and

Multiswitcher • SISProgramming and Control

Information request

With verbose 2/3 activated

 

 

GGeneral information

I/i

I/i

Query part number

N/n

N/n

Query part number for slots

*N/n

*N/n

Where:: X\ = Output (card) type

 

A = Universal scaler

D =Dual-output wideband

B = Video-only scaler

E = Scan converter

C = Single-output wideband

 

X = No output present

Z = Internal wideband output (outputs 1 and 2)

Inf X\•X\•X\•X\

Query the configuration of all

•X\•X\•X\•X\]

outputs (listed 1-8).

Pno60-787-01]

View the part number (based

 

unit).

PPno60-787-01.X\

View the part number (slot

X\ X\ X\]

population from slot 1-4).

Control, cont’d

Page 88
Image 88