Operation and Setup, cont’d

Resetting the Unit with the Reset Button

There are four reset modes (numbered 1, 3, 4, and 5 for the sake of comparison

with Extron IPL products) that you can access by pressing the Reset button on the

rear panel. The Reset button is recessed, so use a pointed stylus, ballpoint pen, or Extron Tweeker to press it. See the table below for a summary of the reset modes.

CReview the reset modes carefully. Using the wrong reset mode may result in unintended loss of flash memory programming, port reassignment, or processor reboot.

NThe reset modes listed in the table close all open IP and Telnet connections and close all sockets. Also, each mode is a separate function, not a continuation from mode 1 to mode 5.

Reset Mode Comparison Summary

Mode

Activation

Result

 

 

Notes

 

 

 

 

 

 

 

1

Hold down the recessed

Mode 1 causes the ISM 824 to revert to the factory

Use mode 1

 

Reset button while applying

default firmware. Event scripting does not start if the

to remove

 

power to the unit

unit is powered on in this mode. All user files and

a version of

 

 

settings (drivers, audio adjustments, IP settings, etc.) are

firmware if

 

 

maintained.

incompatibility

 

 

 

 

 

 

issues arise.

 

 

 

 

 

 

3

Hold down the Reset button

Mode 3 turns events on or off. During resetting, the Reset

Events must

 

for about 3 seconds, until

LED flashes 2 times if events are starting; 3 times if events

be turned on

 

the Reset LED blinks once.

are stopping.

if you want

 

Then, within 1 second, press

 

 

 

 

to change IP

 

Reset again briefly (for less

 

 

 

 

settings or

 

than 1 second).

 

 

 

 

scheduling.

4

Hold down the Reset button

Mode 4 does the following:

Mode 4 enables

 

for about 6 seconds, until

• Enables ARP capability.

you to set

 

the Reset LED has blinked

• Sets the IP address back to factory default.

IP address

 

twice (once at 3 seconds,

Sets the subnet back to factory default.

information

 

once at 6 seconds). Then,

• Sets the default gateway address back to the factory

using ARP

 

within 1 second, press

and the MAC

 

default.

 

Reset briefly (for less than 1

address.

 

• Sets port mapping back to factory default.

 

second).

 

 

• Turns DHCP off.

 

 

 

 

 

 

Turns all events off.

 

 

 

The Reset LED flashes 4 times in quick succession during

 

 

 

reset

 

 

 

 

 

 

 

5

Hold down the Reset button

Mode 5 performs a complete reset to factory defaults

Mode 5 is

 

for about 9 seconds, until

(except the firmware).

useful if

 

the Reset LED has blinked

• Does everything mode 4 does.

you want to

 

three times (once at 3

• Resets everything that was set via the Real Time

start over

 

seconds, once at 6 sec., once

Adjustments

with control

 

at 9 seconds). Then, within

 

part of the control program: all video settings and

software

 

1 second, press Reset briefly

miscellaneous

configuration

 

(for less than 1 second).

 

options.

and uploading,

 

 

Resets all IP options.

and to replace

 

 

Removes/clears all files from the processor.

events.

 

 

 

 

 

The Reset LED flashes 4 times in quick succession during

 

 

 

the reset.

 

3-44 ISM 824 Integration Scaling Multiswitcher • Operation and Setup

Page 76
Image 76
Extron electronic ISM 824 manual Resetting the Unit with the Reset Button, Reset Mode Comparison Summary