LG Electronics General Wall Mounted-Inverter Type manual Part 4 Trouble Shooting

Models: General Wall Mounted-Inverter Type

1 67
Download 67 pages 5.96 Kb
Page 40
Image 40

Part 4 Trouble Shooting

2. Check temperature and pressure of refrigeration cycle.

Suction pressure

Temperature

 

 

(Compared with

(Compared with

Cause of Trouble

Description

the normal value)

the normal value)

 

 

 

 

 

 

 

High

Defective compressor

Current is low.

Higher

 

 

 

Normal

Excessive amount of

High pressure does not quickly

 

 

 

refrigerant

rise at the beginning of operation.

 

 

 

 

 

 

Insufficient amount of

Current is low.

Lower

Higher

refrigerant(Leakage)

 

 

 

Clogging

 

 

 

 

 

NOTICE

1.The suction pressure is usually 8.5~9.5 kg/cm2.g at normal condition.

2.The temperature can be measured by attaching the thermometer to the low pressure tubing and wrap it with putty.

40Room Air Conditioner

Page 40
Image 40
LG Electronics General Wall Mounted-Inverter Type manual Part 4 Trouble Shooting