LG Electronics General Wall Mounted-Inverter Type manual Healthy Dehumidification operation

Models: General Wall Mounted-Inverter Type

1 67
Download 67 pages 5.96 Kb
Page 11
Image 11

Part 2 Functions & Controls

2.3 Healthy Dehumidification operation

When the dehumidification operation is set by the remote controller, the intake air temperature is detected and the set- ting temp. is automatically set according to the intake air temperature.

Intake air Temp.

Setting Temp.

26°C(78.8°F) intake air temp.

25°C(77°F)

 

 

24°C(75.2°F) intake air temp.< 26°C(78.8°F)

intake air temp. -1°C(-2°F)

 

 

22°C(71.6°F) intake air temp. < 24°C(75.2°F)

intake air temp. -0.5°C(-1°F)

 

 

18°C(64.4°F) intake air temp. < 22°C(71.6°F)

intake air temp.

 

 

intake air temp. < 18°C(64.4°F)

18°C(64.4°F)

When intake air temp. is 1 C(2 F) above the setting temp., condition of compressor is same as in cooling mode operation.

When intake air temperature reaches 1 C(2 F) below the setting temp., compressor operates in step1~step3 and the indoor fan speed again operates at low speed or comes to a stop.

2.4 Automatic operation

When the Auto operation is set by the remote controller, the intake air temperature is detected and the setting temp. is automatically set according to the intake air temperature and operation mode.

The air volume is automatically set according to the intake air temperature.

2.5 Auto changeover operation

The air conditioner changes the operation mode automatically to keep indoor temperature steady.

When room temperature vary over ±2°C(±4°F) with respect to setting temperature, air conditioner keeps the room tem- perature in ±2°C(±4°F) with respect to setting temperature by changing the mode from cooling to heating and vice versa.

+4°C(+8°F) Switching point

+2°C(+4°F) Heating thermo off +0.5°C(+1°F)

Setting

Temp.

-0.5°C(-1°F) Cooling thermo off

-2°C(-4°F) Switching point

Mode

Cooling

Heating operation

Cooling

operation

operation

 

 

Service Manual 11

Page 11
Image 11
LG Electronics General Wall Mounted-Inverter Type manual Healthy Dehumidification operation, Automatic operation